Operation Details - Panasonic cs-pa7dkd Service Manual

Air circulation up to 10.10 m3/min
Table of Contents

Advertisement

8 Operation Details

8.1
Cooling Mode Operation
When selecting the Cooling Mode Operation, the unit will operate according to the setting by the Remote Controller or
the control panel on the indoor unit and the operation is as the following.
Time Delay Safety Control
3 min.----If the compressor stops, it will not restart within 3 minutes.(Protection of compressor).
7 Minutes Time Save Control
7 min.----The unit will automatically operate in 7 minutes even if the room temperature is not reached.
(Prevention of raising the humidity)
Anti-Freezing Control
If temperature of evaporator is lower than 2
for 4 minutes, the compressor will cease to prevent the
evaporator from freezing. Fan speed setting will not be
changed.
When temperature of evaporator reaches 10 ,compressor
will restart.
During Cooling Mode Operation, the Time Delay Safety
Control is available.
Automatic Fan Speed Mode
During Cooling Mode Operation, use remote controller to select Automatic Fan Speed.
Fan speed will be at the point between "High speed" and "Medium speed".
Deodorization control.
1 Fan speed will be at
2 Fan speed will be at Me when the compressor restarts.
.
continuously
Slow
Indoor Fan
STOP
40
30
Compressor
ON
Hi till the compressor ceases (set temperature reached).
Evaporator
Temperature
( )
1
Slow
Slow
STOP
20
160
STOP
21
CS-PA7DKD / CU-PA7DKD / CS-PC7DKD / CU-PC7DKD
10
4 minutes
2
Compressor ceases
Time
2
Slow
STOP
40
30
ON
Restart