Indoor Unit Installation - Panasonic cs-pa7dkd Service Manual

Air circulation up to 10.10 m3/min
Table of Contents

Advertisement

9.3.2.

Indoor unit Installation

The mounting wall is strong and solid enough to prevent it from
vibration.
1. Mount the installation plate on the wall with four
installation plate fixing screws.
(If mounting the unit on the concrete wall,consider
using anchor bolts.)
Always mount the installation plate horizontally by
aligning the mark-off line with the thread and use a
level gauge.
Screw
2
E
105mm
C
B
Thread
Weight
Fig.5
2. Drill the piping hole with 70mm
hole-core drill.
Line according to the arrows marked on the lower left and
right side of the installation plate.
To drill a hole in the wall and install a sleeve for tube ass'y
Drill a
70mm hole sloping downward toward the outside of
the wall.
Insert the sleeve for tube ass'y through the hole.
Fix the bushing to the sleeve.
Extrude 15mm of the sleeve then cut
.
Caution
When the wall is horrow please be sure to use the sleeve
for tube ass'y to prevent dangers caused by mice biting
the connecting cable.
Finish by sealing the sleeve with putty or caulking
compound at the final stage.
Installation
plate
1
A
145mm
B
The lower left and right side of installation plate
Left rear piping
Center
70mm
7 0mm
Indoor
70mm
39
CS-PA7DKD / CU-PA7DKD / CS-PC7DKD / CU-PC7DKD
Right rear piping
Center
70mm
7 0mm
Wall
Indoor
Outdoor
5-7mm
Fig.6
Outdoor
15mm
5-7mm
Fig.7