Soft Dry Mode Operation - Panasonic cs-pa7dkd Service Manual

Air circulation up to 10.10 m3/min
Table of Contents

Advertisement

CS-PA7DKD / CU-PA7DKD / CS-PC7DKD / CU-PC7DKD
Time Graph for Cooling Operation
Set temperature
8.2.

Soft Dry Mode Operation

Operation area
COOLING(OFF)
DRY(ON
DRY(OFF)
When selecting Soft Dry mode operation, the operation will be cooling until the room temperature reaches the set temp on
remote control, and then Soft Dry will be activated. (During Soft Dry Mode the fan of indoor unit will operate at super low
speed. The soft dry mode will run for less than 10 minutes.)
Once Soft Dry mode operation is turned off, indoor fan, compressor and outdoor fan will stop for 6 minutes.
Time Delay Safety Protection
During cooling mode operation, if the compressor ceased, it will not restart within 3 minutes.
Anti Freezing Control
Same as the denotation in Cooling Operation.(
(During Soft Dry Mode Operation, compressor will stop for at least 6 min.)
a b c d e f g h i j k l m n o p q r s t u v w x y z
Intake air temperature
Start
1.5
Stop
31
29
1
Basic Time
Comp.
Indoor Fan
Outdoor Fan
Operation Indicator
Operation status
d - g
Time delay safety control
:
:
g - h
Compressor Test control
h - o
:
Auto restart control
:
q - t
Anti-freezing Control
COOLING
DRY
DRY(OFF)
P21
)
10
Evaporater
temperature
2
1
3
7
1'
Time
COOLING(ON)
1.5
1.0
DRY(ON)
22
3
4'
Operate
Stop

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents