IPX4D
These appliances comply with the S.E.D.B.U.K. scheme, band "D"
Please refer to commissioning instructions for filling in the log book
Note: All CORGI registered installers carry a CORGI ID Card.
You can check your installer is CORGI Registered by calling 01256 372300
Please remember to carry out the following checks after installation. This will achieve complete customer satis-
faction, and avoid unnecessary service calls. A charge will be made for a service visit where the fault is not due to
a manufacturing defect.
– Has a correct by-pass been fitted and adjusted?
– Has the system been flushed in accordance with the guidelines given in BS7593 "Treatment of water in domes-
tic hot water central heating systems"?
– Is the system and boiler full of water, and the correct pressure showing on the pressure gauge?
– Is the Auto Air Vent open?
– Has the pump been rotated manually?
– Is the gas supply working pressure correct?
– Is the boiler wired correctly? (See installation manual).
– Has the D.H.W. flow rate been set to the customer requirements?
– Has the customer been fully advised on the correct use of the boiler, system and controls?
– Has the log book provided been completed?
Supplied By www.heating spares.co Tel. 0161 620 6677
Format 80 C:
Gas Council number 47-719-12
Format 100 C:
Gas Council number 47-719-13
Format 110 C:
Gas Council number 47-719-21
SIME COMBINATION BOILERS
Installer checklist