General Machine Cleaning; Knife Adjustment; Feed Open Interlock Switch Adjustment - Paxar 545 User Manual

Paxar model 545 printer users manual
Table of Contents

Advertisement

General Machine Cleaning

Knife Adjustment

Feed Open Interlock Switch Adjustment

Users Manual Model 545™
The machine should be cleaned every eight hours of use or as needed. With the
exception of the print heads and the optical sensors, the machine can be cleaned
using an alcohol base solution. Simply apply a liberal amount of alcohol to a clean
rag and wipe down the machine components starting at the unwind and ending at the
stacker.
Printheads
Refer to the Automated Print Head and Manual Manifold Cleaning sections for
cleaning the print heads.
NOTE: The print head guards can be cleaning with alcohol.
Optical Sensors
When an erroneous interlock condition occurs or print registration in reference to a
sense mark becomes inconsistent or erratic - a sensor may need to be cleaned.
Always use clean supplies when cleaning sensors. Never use anything abrasive on
any of the sensors. Never use an alcohol based solution on any of the sensors. Dry
air or a foam swab are the recommended supplies to use when cleaning a sensor.
Either blow the dust / debris from the sensor using dry clean compressed air or wipe
the sensor with a dry clean swab.
The knife has an adjustment to square the cut to the fabric. To make
the adjustment, loosen the two cap screws, one on top of the knife and
one below the knife, using the 3/16" ball driver. Move the knife in
the direction desired to square the cut and retighten.
With the machine rear cover removed - while turning the feed lever knob back and
forth you should heard the switch clicking. If not, the switch bale is adjusted by
carefully bending it as needed.
Maintenance • 61

Advertisement

Table of Contents
loading

Table of Contents