Gas cate-
I2H
gory:
13.6 Gas burners
BURNER
NORMAL POWER
kW
Auxiliary
Semi-rapid
Triple Crown
13.7 Gas Connection
Use a flexible pipe in compliance with
the regulation in force. Make sure they
do not come in touch with mobile parts
and are not squeezed.
WARNING!
Only a qualified and
competent person can do
the gas installation. Before
you connect te gas,
disconnect the appliance
from the electricity supply or
switch off the fuse in the fuse
box. Close the primary valve
of the gas supply.
Supply piping should not be
less than R3/8. Connection is
made to the Rc 1/2 (1/2
" B.S.P.) female threaded.
The entry pipe is located just
below the hob level on the
rear left hand side of the
appliance. The gas supply
ramp is on the rear side of
the appliance.
Gas sup-
ply
Natural Gas
INJECTOR MARK 1/100
mm
1
1.9
3.4
G20 (2H) 20 mbar
Btu/h
70
96
136
WARNING!
Only liquid sealants can be
used when the inlet gas pipe
is fitted i.e.: do not use the
P.T.F.E. sealant tape. When
the installation is complete,
carry out a gas tightness test
and make sure that the seal
of each pipe fitting does not
leak.
Use flexible tubing, which
comply with the BS.669
current edition.
A
B
C
WARNING!
The gas bayonet connector
must be in the marked area.
ENGLISH
27
3412
6483
11600
E
D
C