STEP   4   T urning   o n   t he   O utput  
16. Press   O utput   O n/Off   t o   t urn   o n   t he   o utput.  
 
Remote   O peration  
 
The   f ollowing   S CPI   c ommand   e xample   e nables   c hannel   2 ,   s ets   t he   v oltage   o utput   t o   2 .22V,   t he   c urrent  
limit   t o   1 .5A   a nd   t urns   t he   o utput   o n.  
 
INST:SEL   C H2  
SOURCE:OUTP:ENAB   O N  
SOURCE:VOLT   2 .22V  
SOURCE:CURR   1 .5A  
SOURCE:OUTP   O N  
 
Combining   C hannels   1   a nd   2   i n   S eries   t o   O utput   M ore   t han   3 0V  
 
The   s eries   2 200   m ulti-­‐channel   p ower   s upplies   h ave   a ll   c hannels   i solated   i n   t heir   d efault   s tate.     H owever,  
channel   1   a nd   c hannel   2   c an   b e   c ombined   i n   s eries   t o   o utput   a   h igher   t otal   v oltage.     T he   f ollowing  
example   d emonstrates   t he   s teps   t o   e nable   a nd   o utput   a   c ombined   v oltage   f rom   c hannel   1   a nd   2 .  
 
Front   P anel   O peration  
STEP   1   C onfigure   t he   I nstrument   t o   S eries   C ombination  
1. Press   M enu.  
2. Use   t he   a rrow   k eys   o r   t he   n avigation   w heel   t o   s elect   C ombine   C H1+CH2.  
3. Press   E nter   t o   e nter   t he   s ubmenu.  
4. Use   t he   a rrow   k eys   o r   t he   n avigation   w heel   t o   s elect   V 1+V2   S eries.  
5. Press   E nter   t o   s et   t o   s eries   c ombination.       S ee   a n   e xample   o f   a   s eries   c ombination   f ront   p anel  
display   b elow.  
 
STEP   2   S etting   t he   V oltage   O utput   a nd   t he   C urrent   L imit  
6. Press   C H1.    
7. Press   V -­‐Set.  
8. Use   t he   a rrow   k eys,   n umeric   k eypad,   o r   t he   n avigation   w heel   t o   e nter   t he   v oltage   o utput.  
9. Press   E nter   t o   s et   t he   v oltage   o f   t he   c ombined   c hannels.  
10. Press   I -­‐Set.  
11. Use   t he   a rrow   k eys,   n umeric   k eypad,   o r   t he   n avigation   w heel   t o   e nter   t he   c urrent   l imit.  
12. Press   E nter   t o   s et   t he   c urrent   o f   t he   c ombined   c hannel.  
STEP   3   T urning   o n   t he   O utput  
13. Press   O utput   O n/Off   t o   t urn   o n   t he   o utput.  
 