Precautions In Servicing; Electrical Parts - HYOSUNG COMET 250/R FI Service Manual

Hide thumbs Also See for COMET 250/R FI:
Table of Contents

Advertisement

4-1-1 FI SYSTEM DIAGNOSIS

PRECAUTIONS IN SERVICING

When handling the component parts or servicing the
FI system, observe the following points for the safety
of the system.
◉ ◉ ELECTRICAL PARTS
▣ ▣ CONNECTOR / COUPLER
● When connecting a connector, be sure to push it
in until a click is felt.
● With a lock type coupler, be sure to release the
lock when disconnecting, and push it in fully till the
works when connecting it.
● When disconnecting the coupler, be sure to hold
the coupler body and do not pull the lead wires.
● Inspect each terminal on the connector / coupler
for looseness or bending.
● Inspect each terminal for corrosion and
contamination.
The terminals must be clean and free of any
foreign material which could impede proper
terminal contact.
● Inspect each lead wire circuit for poor connection
by shaking it by hand lightly. If any abnormal
condition is found, repair or replace.
● When taking measurements at electrical
connectors using a tester probe, be sure to insert
the probe from the wire harness side (backside) of
the connector / coupler.
10