JUKI SC-920 Instruction Manual page 34

Hide thumbs Also See for SC-920:
Table of Contents

Advertisement

⑨ Sewing counting function (Function setting No. 14)
The function counts up every time thread trimming is completed and counts the number of completion of the
sewing process.
1 4
(Caution) The sewing counter can only be operative when the CP-180 is used with the sewing machine.
The counter indication changes as shown below according to the combination of setting No. 6 and setting No.
14.
Setting No. 6
Setting No. 14
1
1
0
0
⑩ Neutral automatic presser lifting function (with AK device only) (Functionsetting No. 21)
This function can automatically lift the presser foot when the pedal is in the neutral position.
Automatic lifting time of the pedal depends on the automatic lifting time after thread trimming and when the
presser foot is automatically lowered, it is automatically lifted at the second neutral position after it has come off
the neutral position once.
2 1
⑪ Needle up/down switch function changeover function (Function setting No. 22)
The needle up/down switch function can be changed over between the needle up/down compensation and one
stitch compensation.
2 2
⑫ Setting of the suction time of the back-tack solenoid (Function setting No. 29)
This function can change the suction time of the back-tack solenoid.
It is effective to decrease the value when the heat is high.
(Caution) When the value is excessively decreased, failure of motion or defective pitch will follow.
Be careful when changing the value.
2 9
2
0 : off
Sewing counting function is inoperative.
1
1 : on
Sewing counting function is operative. (Every time thread trimming is
performed)
2 : on
External sewing counter switch input.
1
Bobbin counter
0
Bobbin counter
1
Sewing counter (only with CP-180)
0
Counter function is ineffective.
0 : off
Function of neutral automatic presser lifting is not operative.
0
1 : on
Selection of function of neutral automatic presser lifting
0 : Needle up / down compensating stitching
0
1 : One stitch compensating stitching
Setting range : 50 to 500 ms <10 / ms>
5
0
Counter
– 32 –

Advertisement

Table of Contents
loading

Table of Contents