Key Access Programming - Paradox Esprit 728 Ultra Programming Manual

Hide thumbs Also See for Esprit 728 Ultra:
Table of Contents

Advertisement

Address
KEY SELECT:
Zone:
092:
Intellizone = ON
Zone:
096:
Silent = ON
Zone:
100:
24Hr./Fire = ON
Keypad zones
cannot be set as
24Hr zones.
Zone:
104:
Instant = ON
Zone:
108:
Follow = ON
Zone:
112:
Delay 2 = ON
Zone:
116:
Zone:
120:
Zone:
124:
Bypass = ON
Fire zones cannot be bypassed.
Do not use the Intellizone feature and an entry delay for the same zone, otherwise an alarm may occur as a user tries to
disarm the system. Zones that are not selected at addresses 100 to 112 (728 Ultra) or 114 (738 Ultra) become "Delay 1" zones.

Key Access Programming

Programs features quickly, without entering addresses or sections numbers. To activate Key Access Programming, press [
followed by the Installer code, Master code or User code 1 (code required depends on the desired feature; see below). Press the key
corresponding to the desired feature. Press [
programming mode.
Key
Feature
[8]
Installer Test Mode
In Installer Test mode, a confirmation beep (intermittent) indicates that the test
mode is enabled. A rejection beep indicates that the test mode is disabled. The
bell will squawk during walk testing to indicate opened, functional zones.
[9]
"Auto Arming" Time Program
Key [9] flashes. Enter 2-digit hour (00 to 23) and 2-digit minutes (00 to 59).
[
]
Panel Time Programming
MEM
[
] key flashes. Enter 2-digit hour (00 to 23) and 2-digit minutes (00 to 59).
MEM
[
]
Test Report
BYP
Reporting is enabled at address 086, keys [
page 10). A value must be entered at address 512 (page 7) and both telephone
and account numbers must be programmed.
[
]
Call Espload Via Telephone
TRBL
Panel identifier and PC password (addresses 004 to 007 on page 3) and
computer telephone number (addresses 008 to 015 on page 3) must be
programmed.
[
] Answer Espload
AWAY
This feature is available when using the ADP-1 adapter. In Espload, "blind dial" must
be activated in the "modem setup" section and panel phone number programmed.
[
]
Cancel Communication Attempts
STAY
Until next reportable event.
[1] [2] [3] [4] [5] [6] [7] [8] [9] [0] [
1
2
3
4
5
6
092:
1
2
3
4
5
6
096:
1
2
3*
4
5
6
100:
* When zone 3 is defined as 24Hr, it becomes a 4-wire smoke detector fire zone (2-wire smoke detector support must be
disabled, address 086 key [
If using 2-wire smoke detectors and ATZ is enabled, zone 3 can be defined as 24Hr (728 Ultra only).
1
2
3
4
5
6
104:
1
2
3
4
5
6
108:
1
2
3
4
5
6
112:
SYSTEM A / STAY
1
2
3
4
5
6
116:
1
2
3
4
5
6
120:
1
2
3
4
5
6
124:
] or [
ENTER
Table 11: Key Access Programming
] and [
STAY
Esprit 728 Ultra & 738 Ultra - 11 - Programming Guide
Table 10: Zone Definition
] [
STAY
FORCE
/[
7
8
9
10
11
7
8
9
10
11
7
8
9
10
11
] = OFF).
BYP
7
8
9
10
11
7
8
9
10
11
7
8
9
10
11
(if ON, zone is armed on Stay or "System A" arming)
7
8
9
10
11
SYSTEM B
(if ON, zone is armed in "System B" arming)
7
8
9
10
11
7
8
9
10
11
] to exit. When communicating with Espload, it is impossible to enter
CLEAR
Codes that can access feature
Installer Code Only
Installer Code, Master Code or User Code 1
Installer Code, Master Code or User Code 1
Installer Code, Master Code or User Code 1
]/[
] (see
AWAY
FORCE
Installer Code, Master Code or User Code 1
Installer Code, Master Code or User Code 1
Master Code/User Code 1 only cancel calls to Espload
The Installer Code can cancel all communications
]
[1]
[2]
]
AWAY
12
13
14
094:
12
13
14
098:
12
13
14
102:
12
13
14
106:
12
13
14
110:
12
13
14
114:
12
13
14
118:
12
13
14
122:
12
13
14
126:
[3]
[4]
[5]
[6]
15
16
17
18
15
16
17
18
15
16
17
18
15
16
17
18
15
16
17
18
15
16
17
18
15
16
17
18
15
16
17
18
15
16
17
18
]
ENTER

Advertisement

Table of Contents
loading

This manual is also suitable for:

Esprit 738 ultra

Table of Contents