Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
55
(Small)(A)
Oven
-
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
Inner dimensions of the oven:
Inner Volume of the Oven:
Innder dimensions of the plate plate warmer:
Voltage and Frequency of Power Supply:
Burners:
adaptable for use with all the types of gas indicated on
Burner and Nozzle Characteristics
Thermal Power
kW (p.c.s.*)
Nominal
Reduced
3.00
0.7
1.90
0.4
1.00
0.4
2.60
1.0
Nominal (mbar)
3

Technical Characteristics

Width: 43.5 cm
Depth: 43.5 cm
Height: 31 cm
Width: 46 cm
Depth: 42 cm
Height: 8.5 cm
see data plate
the data plate
Liquid Gas
By-Pass
Nozzle
Flow*
1/100
1/100
(mm)
(mm)
***
41
86
218
30
70
138
30
50
73
52
78
189
28-30
20
35
S
S
R
A
K6 G20/R
K6 G21/P
This appliance conforms with the following
European Economic Community directives:
-
2006/95/EC of 12/12/06 (Low Voltage) and subsequent
modifications;
-
2004/108/EC of 15/12/04 (Electromagnetic
Compatibility) and subsequent modifications;
-
2009/142/EC of 30/11/09 (Gas) and subsequent
litri 58
modifications;
-
93/68/EC of 22/07/93 and subsequent modifications.
- 1275/2008 (Stand-by/ Off mode)
The European Directive 2002/96/EC on Waste Electrical
and Electronic Equipment (WEEE), requires that old
household electrical appliances must not be disposed of
in the normal unsorted municipal waste stream. Old
appliances must be collected separately in order to optimise
the recovery and recycling of the materials they contain
and reduce the impact on human health and the
environment. The crossed out "wheeled bin" symbol on the
product reminds you of your obligation, that when you di-
spose of the appliance it must be separately collected.
Consumers should contact their local authority or retailer
for information concerning the correct disposal of their old
appliance.
17
Natural Gas
Nozzle
Flow*
g/h
1/100
l/h
**
(mm)
214
116
286
136
106
181
71
79
95
186
119
248
37
20
25
17
45
25
Nozzle
Flow*
1/100
l/h
(mm)
143
286
118
181
80
95
132
248
13
6,5
18

Advertisement