Indesit K6G20/R Installation And Use Manual page 16

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
c) Minimum regulation of the hob burners:
Turn the tap to minimum;
• Remove the knob and adjust the regulation screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
N.B.: In the case of liquid gas, the regulation screw
must be screwed in all the way.
• Check that the flame does not go out when you turn the
tap quickly from high to low.
d) Regulating the primary air of the burners: The primary air
of the burners does not need to be regulated.
Adapting to different types of gas
In order to adapt the oven to a different type of gas with
respect to the gas for which it was manufactured (indi-
cated on the label), follow these simple steps:
a) Replacing the oven burner nozzle
• open the oven door fully
• pull out the sliding oven bottom
• unscrew the burner fastening screws
• remove screw "V" and then the oven burner;
• Unscrew the oven burner nozzle using the special
socket spanner for the nozzles, or a 7 mm socket span-
ner, and replace it with a nozzle suited to the new type
of gas (see Table 1).
Take particular care handling the spark plug wires
and the thermocouple pipes.
• Replace all the parts, following the steps described
above in the reverse order.
b) Regulating the minimum for the gas oven burner with ther-
mostat:
• Light the burner as described in the paragraph "The Oven
Knob" in the instruction booklet;
• urn the knob first to the Max setting for about 10 minutes
and then to Min;
• Remove the knob;
• Adjust the screw located outside the thermostat pin
until the flame is small but steady;
N.B.: In the case of liquid gas, the adjustment screw
must be screwed all the way in.
• Check that the burner does not turn off when you turn the
knob from Max to Min and when you open and close the
oven door quickly.
Regulating the Primary Air for the Oven Burner
The oven burner do not need to be regulated in terms of
primary air.
Important
On completion of this operation, replace the old rating sticker
with one indicating the new type of gas used. This sticker is
available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in compliance
V
with current National Regulations relative to "regulators for
channelled gas".
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

K6g21/p

Table of Contents