Overview
This chapter provides detailed lists of all system specifications in an easy-to-follow table format.
Note: The following specifications are subject to change without notice.
Electrical Characteristics
Power Supply
S-ICX Cabinet
Primary Power -
Input @ AC:
AC Frequency:
Maximum Power Dissipation (VA):
Maximum Peak AC Input Current:
DC Voltage Output Specification:
AEC (8-circuit card that supports single-line devices
such as rotary and DTMF standard phones; FAX
machines; dictation equipment; etc.) -
Ring Voltage:
Ringing Capability:
Traffic Rating Characteristics:
S-ICX key telephones
Battery Backup
Battery Pack: (Part No. VB-44026)
Capacity (with maximum traffic):
Battery Charger Characteristics -
Charger:
Nominal Voltage:
Battery Discharge Cut-Off Voltage:
72
Chapter 6 - Specifications
Equipment
Equipment
S-ICX (International) issued October 2000
Specification/Requirements
200 - 240V AC
230V +10%
50/60 Hz
336VA
1.4A
+24 volts DC (+26.0 to +27.6 volts DC)
+5 volts DC (+4.9 to +5.3 volts DC)
150 volts p-p
2.0 REN per circuit
6 ACS per station system-wide
3 watts maximum (powered from the S-ICX)
Specification
15 minutes
Constant voltage and constant current charge
27.2 volts
21.0 + 0.3 volts DC
S-ICX-50-200