Connecting the assembly cable

Cable specification
✴✴12/18✴✴
• Connect the power cable to the auxiliary circuit breaker . If every pole fails to connect to the power supply, it
must be incorporated in a wire with a contact opening of ≥ 3 mm .
• For each model use specified cable only as written in blow table . Failing to do that may result to damage of
appliance, re, accident or even explosion
Connecting the cable
When you install the unit, first make the refrigerant connections and then electrical connections .
Connect the air conditioner to grounding system before performing the electrical connection .
If unit is uninstalled, first disconnect electrical cables, then refrigerant connections .
If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable .
1. Extend the assembly cable if necessary.
• Do not connect two or more different cables to extend the length .
It may cause fire .
2. Open the front grille panel.
3. remove the screw securing the connector cover.
4. Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals.
(Refer to the picture below)
• Each wire is labeled with the corresponding terminal number .
5. Pass the other end of the cable through the 65 mm hole in the wall.
6. Close the connector cover by tightening the screw carefully.
7. Close the grille panel.
8. remove the terminal board cover on the side of the outdoor unit.
RAC BORACAY_EN_Eco-inverter IBIM_05124A-00.indd 39
Model
✴✴24✴✴
English-39
Interconnection cable
4G X 1 . 5 mm
²
, H07RN-F
3G X 1 . 0 mm
²
, H07RN-F
1 X 0 . 7 5mm