User Type

The user type defines the level of access the user has in order to operate and program the
system. User 00 (Engineer) and User 01 (Master) types cannot be changed. Users 02
through to 10 can be assigned to user types 3 to 9 as shown in the table below:
No
Type & Description
0
Not in Use
The selected user is not in use.
1
Engineer
The selected user is an engineer and can access all options within the engineer's program
menu. This type can only be selected by the engineer.
2
Technician
The selected user is a Technician and can access all options except the onboard
communication options within the engineer's program menu. This type can only be selected
by the engineer.
3
Master
The selected user is a Master user and can access all options within the user menu and
program new users.
4
Manager
The selected user is a Manager user and can access all options within the user menu.
5
Standard
The selected user is a Standard user and can access the following options from the user
menu: "Away Arm", "Stay Arm 1/2/3", "Do walk Test" and "Change Code".
6
Cleaner
The selected user is a Cleaner and can access the following options from the user menu:
"Away Arm" and "Stay Arm 1/2/3". The cleaner code can only disarm the system if the
cleaner code was used to arm the system. If the system was armed by another user type
and a cleaner code is entered whilst the system is armed or during the entry procedure, the
zones that have the "Cleaner" attribute are bypassed and the entry procedure is cancelled.
When the cleaner is ready to leave the premises, entering their code will start the exit
procedure and at the end of the exit procedure the "Cleaner" zones are reinstated.
7
Arm Only
The selected user is an Arm Only user and can only access the arming options within the
user menu
8
Duress
The selected user is a Duress user and operates the same as a standard user, however, on
entering the access code a silent duress alarm is generated and if programmed, the event
is signalled to alarm receiving centre.
9
Access Control
The selected user is an Access Control user and on entering the access code the relevant
"User Access" and "Door Access" output is activated.
28
P0031-LU-01.00