LCD
P0031-LU-01.00
LED
Description
ACOff
The mains ac supply has been switched off.
ACOn
The mains ac supply has been restored.
BF
Battery fault #? (1: Presence Fail; 2: Load Test Fail).
BR
Battery fault restored.
The system standby battery voltage is low (The system
LB
is running on battery only).
TD
The system time and date has been changed.
ENON
The engineer access code has been entered.
ENOF
The engineer has logged off.
BFAL
The bell fuse has gone open circuit (electronic fuse).
BFAR
The bell fuse has restored.
The auxiliary 12V fuse has gone open circuit (electronic
AFAL
fuse).
AFAR
The auxiliary 12V fuse has restored.
BFAL ?
The battery fuse has gone open circuit (electronic fuse).
BFAR
The battery fuse has restored.
BTAL
The control panel box tamper has been activated.
BTAR
The control panel box tamper has restored.
RTAL ?
Keypad ? box tamper has been activated.
RTAR ?
Keypad ? box tamper has restored.
RL ?
Device ?? on network lost.
RF ?
Device ?? on network found.
TS
User walk test mode started.
TE
User walk test mode ended.
BTS
User bell test started.
BTE
User bell test ended.
An automatic test call was sent to the Alarm Receiving
ATC
Centre (ARC).
A manual (user) test call was sent to the Alarm
TC
Receiving Centre (ARC).
CT ? ON
Control Timer ? is on.
CT ? OFF
Control Timer ? is off.
TS ??
Zone soak test has started and will run for ?? days.
TF ??
Zone ?? has failed whilst on test.
First activation from zone ??. The zone has the "Double
FN ??
Knock" attribute.