Troubleshooting

Before performing any work on the blower, remove the connecting cord plug from the machine's socket.
Condition
Blower does not start when switched on
40
Cause
No electrical contact between connect-
ing cord and blower or battery
Battery has low charge
(1 LED on battery flashes green)
Battery too hot / too cold
(1 LED on battery glows red)
Fault in battery
(4 LEDs on battery flash red)
Blower is too hot
(3 LEDs on battery glow red)
Electromagnetic problem or fault in the
blower
(3 LEDs on battery flash red)
Moisture in blower and/or battery
Remedy
Disconnect cord between battery and
blower, inspect the cord and contacts,
reconnect the cord to the battery and
blower.
Charge the battery
Allow battery to cool down / allow battery
to warm up slowly at temperatures of
about 15°C - 20°C (60°F - 70°F)
Disconnect and reconnect cord between
battery and blower. Switch on the blower
– if the LEDs continue to flash, the bat-
tery has a malfunction and must be
replaced.
Blower is too hot – allow it to cool down.
Disconnect and reconnect cord between
battery and blower. Switch on the blower
– if the LEDs still flash, the blower has a
malfunction and must be checked by a
1)
servicing dealer
.
Allow blower / battery to dry