2.2.

WH-SD30BE5-1 WH-UD30BE5-1

Item
Performance Test Condition
Heating Capacity
COP
Noise Level
Air Flow
Refrigeration Control Device
Refrigeration Oil
Refrigerant (R410A)
Dimension
Net Weight
Pipe Diameter
Standard Length
Pipe Length Range
I/D & O/D Height Difference
Additional Gas Amount
Refrigeration Charge Less
Compressor
Fan
Heat Exchanger
Item
Power Source (Phase, Voltage, Cycle)
Input Power
Maximum Input Power
Starting Current
Running Current
Maximum Current
Power Factor
Power factor means total figure of compressor and outdoor fan motor.
Power Cord
Thermostat
Protection Device
Height
Width
Depth
Liquid
Gas
Type
Motor Type
Rated Output
Type
Material
Motor Type
Input Power
Output Power
Fan Speed
Fin material
Fin Type
Row × Stage × FPI
Size (W × H × L)
Number of core
Length
Unit
kW
BTU/h
kJ/h
W/W
BTU/hW
dB (A)
Power Level dB
3
3
m
/min (ft
/min)
3
cm
kg (oz)
mm (inch)
mm (inch)
mm (inch)
kg (lbs)
mm (inch)
mm (inch)
m (ft)
m (ft)
m (ft)
g/m (oz/ft)
m (ft)
kW
W
W
rpm
mm
Unit
ø
V
Hz
kW
kW
A
A
A
%
m (ft)
7
Outdoor Unit
EUROVENT
9.00
30700
32400
4.10
14.0
53
67
55.1 (1945)
Expansion Valve
FV50S (900)
1.45 (51.2)
795 (31-5/16)
900 (35-7/16)
320 (12-19/32)
66 (146)
6.35 (1/4)
15.88 (5/8)
7 (23.0)
3 (9.8) ~ 30 (98.4)
20 (65.6)
30 (0.3)
10 (32.8)
Hermetic Motor
Brushless (4-poles)
1.70
Propeller Fan
PP
Transistor (8-poles)
60
640
Aluminium (Pre Coat)
Corrugated Fin
2 × 30 × 17
38.1 × 762 × 873.8 : 903.8
Single
230
50
2.20
4.37
10.10
10.10
20.0
95
-
-
Electronic Control
Electronic Control