Panasonic WH-UD30BE5-1 Service Manual page 4

Air-to-water heatpump
Hide thumbs Also See for WH-UD30BE5-1:
Table of Contents

Advertisement

19. The unit is only for use in a closed water system. Utilization in an open water circuit may lead to excessive corrosion of the water
piping.
20. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.
21. Do not dismantle refrigerant piping using pipe wrench. It might deform the piping and cause the unit to malfunction.
22. Select a location where in case of water leakage, the leakage will not cause damage to other properties.
23. Do not locally purchase electrical parts of the product for the purpose of installation, service, maintenance and etc. They might cause
electrical shock or fire.
24. Do not branch the power from terminal block to heater tape. Overloaded terminal block will cause electrical shock or fire.
25. Installation or servicing work. It may need two people to carry out the installation or servicing work.
26. Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single outlet with
other electrical appliances. Poor contact, poor insulation or over current will cause electrical shock or fire.
27. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare
may break and cause refrigerant gas leakage.
1. Do not install the air-to-water heatpump indoor unit and outdoor unit at place where leakage of flammable gas may occur. In case gas
leaks and accumulates at surrounding of the unit, it may cause fire.
2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage
the furniture.
3. It may need two persons to carry out the installation work. The weight of indoor / outdoor unit might cause injury if carried by one
person.
4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury.
5. Select an installation location which is easy for maintenance.
6. Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F - 70°F (30°C - 40°C) higher. Please
use a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F / 600°C).
7. Power supply connection to the indoor unit.
1. Power supply point should be in easily accessible place for power disconnection in case of emergency.
2. In some countries, permanent connection of Air-to-Water Heatpump to the power supply is prohibited.
3. Use the power supply cord 3 x 4.0 mm
4. Connect the power supply cord of the indoor unit to the mains using one of the following methods.
a. Power supply connection to the receptacle using power plug. Use an approved 20A power plug with earth pin for 2.5HP
(SD/UD24BE5-1) and 20A for 3.0HP (SD/UD30BE5-1) for the connection to the socket.
b. Power supply connection to a circuit breaker for the permanent connection. Use an approved 20A circuit breaker for 2.5HP
(SD/UD24BE5-1) and 20A for 3.0HP (SD/UD30BE5-1) for the permanent connection. It must be a double pole switch with
a minimum 3.0 mm contact gap.
8. Do not release refrigerant during piping work for installation, servicing, re-installation and during repairing a refrigeration parts. Take
care of the liquid refrigerant, it may cause frostbite.
9. Do not install this appliance in a laundry room or other high humidity location. This condition will cause rust and damage to the unit.
10. Make sure the insulation of power supply cord does not contact to hot part (i.e. refrigerant piping, water piping) to prevent from
insulation failure (melt).
11. Do not sit, step or place anything on the unit, you may fall down accidentally.
12. Do not touch the sharp aluminium fin, sharp parts may cause injury.
13. After installation, check the water leakage condition in connection area during test run. If leakage occur, it will cause damage to other
properties.
14. The unit described in this manual is designed for use in a closed water system only. Utilization in an open water circuit may lead to
excessive corrosion of the water piping.
2
type designation 60245 IEC 57 or heavier cord.
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-ud24be5-1Wh-sd30be5-1Wh-sd24be5-1

Table of Contents