Safety Limit #2
Harvest time exceeds 3.5 minutes for 6 Consecutive
harvest cycles.
Possible Cause Checklist
Improper Installation
•
Refer to "Installation and Visual Inspection Checklist"
on page 60.
Water System
•
Water area (evaporator) dirty
•
Dirty/defective water dump valve
•
Vent tube not installed on water outlet drain
•
Water freezing behind evaporator
•
Plastic extrusions and gaskets not securely mounted
to the evaporator
•
Low water pressure (20 psig min.)
•
Loss of water from sump area
•
Clogged water distribution tube
•
Dirty/defective float valve
•
Defective water pump
Electrical System
•
Ice thickness probe out of adjustment
•
Ice thickness probe dirty
•
Bin switch defective
•
Premature harvest
Refrigeration System
•
Non-OEM components
•
Improper refrigerant charge
•
Defective harvest valve
•
TXV flooding (check bulb mounting)
•
Defective fan cycling control
70
Part Number STH047 5/16