Koolaire KY0275W Technician's Handbook page 70

Undercounter ice machines
Table of Contents

Advertisement

Safety Limit #2
Harvest time exceeds 3.5 minutes for 6 Consecutive
harvest cycles.
Possible Cause Checklist
Improper Installation
Refer to "Installation and Visual Inspection Checklist"
on page 60.
Water System
Water area (evaporator) dirty
Dirty/defective water dump valve
Vent tube not installed on water outlet drain
Water freezing behind evaporator
Plastic extrusions and gaskets not securely mounted
to the evaporator
Low water pressure (20 psig min.)
Loss of water from sump area
Clogged water distribution tube
Dirty/defective float valve
Defective water pump
Electrical System
Ice thickness probe out of adjustment
Ice thickness probe dirty
Bin switch defective
Premature harvest
Refrigeration System
Non-OEM components
Improper refrigerant charge
Defective harvest valve
TXV flooding (check bulb mounting)
Defective fan cycling control
70
Part Number STH047 5/16