K270 Condenser Fan Motor Access

Access to remove, clean or replace the condenser fan/
motor can be obtained by performing the following:
1. Disconnect electrical power to the ice machine at
the electrical service disconnect.
2. Remove the screws that secure the condenser to the
cabinet and the base to the cabinet.
3. Slide the base forward until contact is made with the
stop screw (approximately 2.5" [6.3 cm]).
Do not move base past the stop screw, tubing
damage could result.
4. Remove right hand screw securing condenser to
base.
5. Pivot condenser forward to obtain 5" (12.7 cm)
between the cabinet and condenser shroud. Take
care not to kink refrigeration tubing.
REMOVE THREE
SCREWS AND
PULL BASE
FORWARD TO
STOP SCREW.
Accessing the Condenser Fan Motor
Part Number STH047 5/16
Caution
,
REMOVE SCREW AND
PVOT CONDENSER TO
OBTAN 5" (12.7 CM)
CLEARANCE BETWEEN
CONDENSER SHROUD.
2.5" (6.3 CM) TO
STOP SCREW
5" (12.7 CM)
CLEARANCE
AFTER
PVOTNG
CONDENSER
CABNET AND
PT1295A