Diagnosing Ice Thickness Control Circuitry - Koolaire KY0275W Technician's Handbook

Undercounter ice machines
Table of Contents

Advertisement

DIAGNOSING ICE THICKNESS CONTROL CIRCUITRY

Ice Machine Does Not Cycle Into Harvest when Water
Contacts the Ice Thickness Control Probe
Step 1
Bypass the freeze time lock-in feature by
moving the ON/OFF/WASH switch to OFF and back to ON.
Wait until the water starts to flow over the evaporator.
Step 2
Clip the jumper wire to the ice thickness probe
and any cabinet ground.
ICE THICKNESS
PROBE
EVAPORATOR
Step 2 Jumper wire connected from probe to ground
Monitoring Harvest Light
The harvest light comes on,
and 6-10 seconds later, ice
machine cycles from freeze to
harvest.
The harvest light comes on but
the ice machine stays in the
freeze sequence.
The harvest light does not
come on.
Part Number STH047 5/16
GROUND
JUMPER WIRE
HARVEST LIGHT
(RED)
The ice thickness control
circuitry is functioning
properly. Do not change any
parts.
The ice control circuitry is
functioning properly. The ice
machine is in a six minute
freeze time lock-in. Verify
Step 1 of this procedure was
followed correctly.
Proceed to Step 3.
PROBE
CONNECTION
BIN SWITCH
LIGHT
(GREEN)
Correction
SV1592i
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kd0273wKy0274aKd0272aKr0270aKy0174aKd0172a ... Show all