INITIAL START-UP OR START-UP AFTER AUTOMATIC

SHUT-OFF

1. Pressure Equalization
Before the compressor starts the harvest valve is
energized for 15 seconds to equalize pressures during the
initial refrigeration system start-up.
2. Refrigeration System Start-up
The compressor starts after the 15-second pressure
equalization, and remains on throughout the entire
Freeze and Harvest Sequences. The harvest valve remains
on for 5 seconds during initial compressor start-up and
then shuts off.
At the same time the compressor starts, the condenser
fan motor (air-cooled models) is supplied with power
throughout the entire Freeze and Harvest Sequences. The
fan motor is wired through a fan cycle pressure control,
therefore it may cycle on and off. (The compressor and
condenser fan motor are wired through the relay. As a
result, any time the relay coil is energized, the compressor
and fan motor are supplied with power.)

FREEZE SEQUENCE

3. Prechill
The compressor is on for 30 seconds prior to water flow to
prechill the evaporator.
4. Freeze
The water pump starts after the 30-second prechill. An
even flow of water is directed across the evaporator and
into each cube cell, where it freezes.
When sufficient ice has formed, the water flow (not the
ice) contacts the ice thickness probe. After approximately
7 seconds of continual water contact, the Harvest
Sequence is initiated. The ice machine cannot initiate a
Harvest Sequence until a 6-minute freeze time has been
surpassed.