Koolaire KY0275W Technician's Handbook page 34

Undercounter ice machines
Table of Contents

Advertisement

D.
Remove the Ice Thickness Probe
COMPRESS SIDES OF
ICE THICKNESS PROBE
NOTE: At this point, the ice thickness probe can easily
be cleaned. If complete removal is desired, follow the
ice thickness probe wire to the bulkhead grommet (exit
point) in the back wall. Pop the bulkhead grommet out
of the back wall by inserting fingernails or a flat object
between the back wall and the grommet and prying
forward. Pull the bulkhead grommet and wire forward
until the connector is accessible, then disconnect the wire
lead from the connector.
Ice Thickness Probe Cleaning
Mix a solution of ice machine cleaner and water
(2 ounces of cleaner to 16 ounces of water) in a
container.
Soak the ice thickness probe a minimum of 10
minutes.
Clean all ice thickness probe surfaces and verify the ice
thickness probe cavity is clean. Rinse thoroughly with
clean water, then dry completely. Incomplete rinsing and
drying of the ice thickness probe can cause premature
harvest.
34
Compress the side of the ice thickness
probe near the top hinge pin and remove it
from the bracket.
Ice Thickness Probe Removal
ICE
THICKNESS
PROBE
Part Number STH047 5/16