Electrical Requirements; Voltage; Fuse/Circuit Breaker; Total Circuit Ampacity - Koolaire KY0275W Technician's Handbook

Undercounter ice machines
Table of Contents

Advertisement

Electrical Requirements

VOLTAGE

The maximum allowable voltage variation is ±10% of the
rated voltage on the ice machine model/serial number
plate at start-up (when the electrical load is highest).
The 115/1/60 ice machines are factory pre-wired with a 6'
(1.8 m) power cord, and NEMA 5-15P-plug configuration.
The 208-230/1/60 and 230/1/50 ice machines are factory
pre-wired with a power cord only, no plug is supplied.

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for each
ice machine. Circuit breakers must be H.A.C.R. rated (does
not apply in Canada).

TOTAL CIRCUIT AMPACITY

The total circuit ampacity is used to help select the wire
size of the electrical supply.
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.
20
Part Number STH047 5/16