Installation Procedure; Connection To The Power Supply; Basic Adjustment Of Sensors To The Ambience; User Interface Initial Calibration - Gorenje IT624ASC Instructions For Use, Installation, And Connection

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18

Installation procedure

CONNECTION TO THE POWER SUPPLY

Basic adjustment of
sensors to the ambience
User interface initial
calibration
The gasket should be attached to the appliance in the following way:
- Remove the protective film from the gasket.
- Then, attach the gasket to the lower side of the glass, approximately 2-3
millimetres from the edge (as shown in the figure). The gasket must be attached
along the entire length of the glass edge and should not overlap at the corners.
- When installing the gasket, make sure that the glass does not come into
contact with any sharp objects.
• Worktop must be placed absolutely horizontal.
• Suitably protect the edges of the cut aperture.
• Connect the cooking hob to the mains power supply (see instructions for
connecting the cooking hob to mains power supply).
• Put the supplied springs in their places.
• Insert the hob into the cut aperture.
• Press the hob firmly towards the worktop from above.
• Connections may be carried out by a qualified technician only. The earthing
protection must comply with the standing regulations.
• Connection terminals are revealed when the connection box cover is removed.
• Prior to any attempted connection, check that the voltage indicated on the
rating plate is in line with your home power supply.
• The rating plate is located underneath the appliance.
• The appliance is manufactured for use with power supply voltage
230-240 V ~.
• In order to make a fixed connection to the mains, insert an all-pole circuit
breaker between the appliance and the mains. This device shall have a contact
separation in all poles, providing full disconnection under overvoltage category III
conditions.
• Such appliances are allowed to be mounted on one side next to a high kitchen
cabinet, the height of which may exceed that of the appliance. On the opposite
side however, only a kitchen cabinet of equal height as the appliance is allowed.
• Upon completion of installation, live wires and isolated cables must be
adequately protected against accidental contact.
Upon each connection to the power supply the sensors of the appliance are
automatically adjusted to the environment to ensure their proper function. All
displays are switched on and fully illuminated for a few seconds.
During the adjustment procedure the sensors must be free of any objects;
otherwise, the adjustment procedure will be interrupted until such objects are
removed from the sensor surface. During this period, regulation of the cooking
hob is impossible.
The hob control panel has implemented an initial keyboard calibration focused to
adapt the sensibility of the keys, to the final mechanical, environmental and user
conditions.
Any time the cooking hob is plugged in or there is a power failure that results in a
reset of the user interface, keyboard sensitivity will be readjusted the first time
the Key Lock is touched. This first touch of the Key Lock must be done in
certain conditions:
▪ Do not use gloves
▪ Use a clean finger.
▪ Touch the glass (smooth touching).
ATTENTION!
Before attempting any repairs on the appliance, disconnect the power supply. In
accordance with the mains voltage, the appliance should be connected in line
with the attached diagram.
The earthing wire (PE) must be connected to the terminal marked with the
earthing symbol.
The connection cable must lead through the relief safety device, protecting it
22

Advertisement

Table of Contents
loading

Table of Contents