Technical data
Installation clearances For operating, service and safety reasons the machine
Installation dimensions
of the water filter
it may be necessary to also observe additional country-specific regulations.
Water and waste piping and connections shall comply with the International
Plumbing Code 2003, International Code Council (ICC), or to the Uniform Plumbing
Code 2003, International Association of Plumbing and Mechanical Officials
(IAPMO)
The local power supply must be constructed according to IEC 364 (DIN VDE 0100).
To improve safety, the device should be fitted with an FI 30 mA earth leakage
current circuit breaker complying with EN 61008. (Type B residual current circuit
breakers provide reliable tripping even if the fault current is smooth. This ensures
a high level of safety.) Near the device or about 11.81 in (30 cm) below the counter
top there should be a shockproof socket as a single-phase connection installed
locally on the rear or side wall of the counter substructure or a country-specific
single-phase socket. If the mains cable for this device is damaged then it must
be replaced by our service personnel or a similarly qualified person, in order to
prevent hazards. The mains cable must not come into contact with hot surfaces.
The mains switch and plug top are part of the on-site installation. The coffee
machine may not be fitted with a fixed permanent mains connection if installed on
a transporting trolley (a mobile station).
In order to avoid possible faults from arising on our shielded data lines due to
potential equalisation currents between the devices, an additional potential
equalisation unit should be planned for devices connected to the vending system.
(See EN 60309)
74
should be installed with a clearance of not less than
1.97 in (50 mm) at the back and sides from the building
or non-WMF components. A minimum working space
of 31.50 in (800 mm) in front of the coffee machine is
recommended. A clear height of 43.31 in (1,100 mm)
in from the top of the supporting surface should be
ensured. The height of the installation surface above
the floor is at least 33.47 in (850 mm). If the coffee
machine connections are to be run downwards through
the counter, please make space for the lines, which can
reduce the usable space below the machine.
See the User Manual for the water filter.