Flush mounting into a countertop is
Flush mounting:
possible.
Flush installation:
The appliance can be installed in the
following temperature- and water-resistant countertops:
Stone countertops
Plastic countertops (such as Corian®)
Solid wood countertops: Only in consultation with
the manufacturer of the countertop (seal cut-out
edges)
Installation in other countertops only in
consultation with the manufacturer of the
countertop.
Installation in countertops made of particleboard is not
possible.
Note: Any cut-out work on the countertop must be
performed in a workshop according to the installation
diagram. The cut-out must be made cleanly and
precisely since the cut-out edge is visible on the
surface. Clean and degrease the cut-out edges with
a suitable cleaning agent (bear in mind silicone
manufacturer's processing instructions).
10
Combining several Vario devices:
VA 420 000/001/010/011 is required for the
combination of several Vario appliances. This is
available separately as a special accessory. Consider
additional space requirement for the connecting strip
between the appliances when making the cut-out
(see installation instructions VA 420 000/001/010/011).
Appliances can also be installed in individual cut-outs,
bearing in mind a minimum distance between the
devices of 2" (51 mm).
When combining several appliances with or without
appliance cover, you can use the appliance extensions
VA 450 110/-400/-600/-800/-900 (depending on
appliance width) to balance out dimension differences.
The connecting strip