Summary of Contents for Gaggenau AI 200-700

  • Page 1 Operating and Assembly Instructions AI 200-700 Extractor Hood...
  • Page 2: Table Of Contents

    AI 200-700 Preface Safety notes Page 3 1. Important notes Page 4-5 1.1 For your safety Page 4 1.2 Operating for the first time Page 5 1.3 About use Page 5 Features Page 6 3. Operation Page 7-9 4. Cleaning and care...
  • Page 3: Preface

    – a large number of control functions, – optimum illumination of the cooking surface by a dimmable halogen light. To ensure that you will be able to use this appli- ance in all its diversity, read through the operating and assembly instructions conscientiously...
  • Page 4: Safety Notes

    3. The fire department is being called. WARNING - TO REDUCE THE RISK OF A 4. You can fight the fire with your back to an exit. RANGE TOP GREASE FIRE. Never leave surface units unattended at high settings.
  • Page 5: Important Notes

    – Adequate incoming air must be ensured if a – Hazardous or explosive substances and vapours wood, coal, gas or oil heater or an open hearth is must not be extracted! operated in the same room as the one in which –...
  • Page 6: Operating For The First Time

    – The appliance must be installed and connected – In the event of malfunctions, first of all check the by a specialist before it is operated for the first household fuses. If the problem has nothing to time.
  • Page 7: Features

    Installation accessories for exhaust air mode Stainless steel-design ventilation duct: LK 010-016 for ceiling heights of 7 ´ ´ 4 ´ ´ - 7 ´ ´ 11 ´ ´ LK 010-026 for ceiling heights of 7 ´ ´ 11 ´ ´ - 9 ´ ´...
  • Page 8: Operation

    (see Fig. 4). When you briefly press the key, the lighting is increased up to the maximum level. You can dim the lighting to the required level by keeping the key pressed. Fig. 4 Fan levels Three fan speeds and one intensive speed are available (see Fig.
  • Page 9 Int key for the intensive level should be pressed when browning and frying in an open pan (see Fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes.
  • Page 10 You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the key and the 1, 2 or 3 key and you can store this setting (see Fig. 9). When delivered, the appliance is set to five minutes, i.e. the combination of the key and the key 2.
  • Page 11: Cleaning And Care

    Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to you indicate to you that you should clean the grease filter (see Fig. 3). The grease filters can of course be cleaned at any time, even if the grease filter saturation display has not started to flash.
  • Page 12: Circulating Air Mode

    Cleaning the extractor hood Clean the exterior of your extractor hood with a soft cloth and mild detergent solution. Do not use any strong, caustic or abrasive cleaning agents. Do not use any abrasive sponges or brushes either. Clean the stainless-steel extractor hood with stainless steel cleaner.
  • Page 13: Maintenance

    – Insert the lamp in the lampholder. Note: do not touch the halogen lamps with your hands. Use a cloth and touch the lamp only on its edges. – Engage the lamp cover. – Connect the appliance to the mains again.
  • Page 14: Assembly Instructions

    If this unit is to be installed over a tub or shower, with a contact gap of at least 3.0 mm.
  • Page 15: Installation

    This hood has been approved for installations as low as 30 ´ ´ and as high as 36 ´ ´ above the cooktop. " " The hood can be used in the exhaust or circulating air mode .
  • Page 16 The manufacturer of the extractor hood accepts no liability for complaints which can The dimensions above refer to a distance of 5 ´ 3 ´ ´ be attributed to the design and layout of the from the floor to the bottom edge of the hood.
  • Page 17 20 mm (Fig. 20). Note: Fig. 20 this hood has been approved for installations as low as 30 ´ ´ and as high as 36 ´ ´ above the cooktop. Circulating air mode only Circulating air mode only:...
  • Page 18 (Fig. 22 and 23). Cut the flexible air pipe to the required length and fix it to the extractor hood. 6. Remove the cover plate from the rear of the support frame (Fig.
  • Page 19 7. Slide the extractor hood into the on the side of the support frame (Note: take care not to trap the mains connecting cable) and immediately secure the hood with 4 screws (Fig. 25). 8. Screw the cover plate back on the rear of the support frame.
  • Page 20 GAGGENAU HAUSGERÄTE GMBH 5551 McFADDEN AVENUE CARL-WERY-STR. 34 · 81739 MÜNCHEN HUNTINGTON BEACH, CA 92649 GERMANY Y (800) 828-9165 · FAX (714) 901-0979 (0 89) 45 90 - 03 FAX (0 89) 45 90 - 23 47 www.gaggenau-usa.com...