    Operating modes Important information Exhaust-air mode Circulating-air mode Prior to installation Coanda effect Exhaust-air mode Circulating-air mode Operating for the First Time Preparing the wall If you encounter a problem Electrical connection Safety instructions Installation Operating procedure Intensive setting Special functions...
  • Page 4: Operating Modes

    If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
  • Page 5: Coanda Effect

    Coanda effect • You do not need to activate the Coanda effect. The Coanda air flow is always active at every fan level. Cooking vapours are extracted particularly well at the front of the cooking field. • The Coanda effect may allow you to operate the extractor hood at a lower, quieter level than you were previously accustomed to.
  • Page 6: Operating For The First Time

    Wait for approx. 1 minute and then switch it on technicians only. again. Improper repairs may put the user at considerable If you have any questions or if a fault occurs, please risk. call Customer Service. Before using your appliance for the first time, (See list of Customer Service representatives).
  • Page 7: Safety Instructions

    Do not place any objects on the extractor hood. manufacturer or his customer service or a similarly The slot for the Coanda air flow must be free at all qualified person in order to prevent serious injury to times.
  • Page 8: Operating Procedure

    Operating procedure The most effective method of removing vapours produced during cooking is to: • Switch the ventilator ON as soon as you begin cooking. • Switch the ventilator OFF a few minutes after you have finished cooking. Fan OFF...
  • Page 9: Intensive Setting

    3, 5 or 10 minutes by simultaneously pressing • Press the 0 button. the Int key and the 1, 2 or 3 key and you can store this setting. When delivered, the appliance is set to five minutes, i.e. the combination of the Int key and the key 2.
  • Page 10: Filters And Maintenance

    The filter mats are made from non-combustible and fold the filters down. metal. At the same time take hold of the underside of Caution: the grease filters with your other hand. As the filter becomes more and more saturated with...
  • Page 11: Activated Carbon Filter

    For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to...
  • Page 12: Cleaning And Care

    See enclosed service booklet for order Wichtig: Es darf keine Flüssigkeit in den Schlitz address. für den Luftaustritt eindringen. • Do not scrape off dried-on dirt but wipe off with Aluminium, coated and plastic surfaces: a damp cloth. • Do not use dry cloths.
  • Page 13: Replacing The Light Bulbsn

    When operating, the fluorescent light bulbs get very hot. Even after a while, there is still a risk of being burnt. Remove the metal-mesh filters (see "Removing and inserting the metal-mesh grease filters").
  • Page 14 10 Insert the metal grease filters (see "Removing and inserting the metal grease filters"). 11 Restore the power by inserting the mains plug or switching on the fuse. Note: If the light does not function, check that the bulbs have been inserted correctly.
  • Page 15: Important Information

    Only one side of the extractor hood may be installed next to a high-sided unit or high wall. Gap at least Please ask your dealer or inquire at your local 50 mm. authority about current means of disposal.
  • Page 16: Prior To Installation

    If the air intake is inadequate, there is a risk of ventilating rooms in which stoves or fireplaces are poisoning from combustion gases which are also located.
  • Page 17: Circulating-Air Mode

    • As few bends in the pipe as possible. hood. • Diameter of pipe to be as large as possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used,...
  • Page 18: Preparing The Wall

    – Live types (e.g. plasterboard, porous concrete, Poroton bricks) use the appropriate fasteners. If you fit your own plug, the colours ofthese wires • may not correspond with the identifying marks on Ensure that the ceiling is capable of providing a the plug terminals.
  • Page 19 Electrical data Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. This extractor hood corresponds to EC regulations concerning RF interference suppression..
  • Page 20: Installation

    Using the drilling template mark the position of the screws on the ceiling. Drill 4 holes Ø 8 mm for the wall plugs. Push the plugs flush with the ceiling. Turn two screws to a 10 mm gap. Both screws...
  • Page 21 Hang the support frame with the two key-holes to the two screws in the ceiling and attach it with all 4 screws to the ceiling. Circulating air mode only: assemble the circulating air switch module and fix it to support frame.
  • Page 22 Slide the extractor hood into the on the side of the support frame (Note: take care not to trap the mains connecting cable) and immediately secure the hood with 4 screws. Screw the cover plate back on the rear of the support frame.
  • Page 23 KF001-010...
  • Page 24 Gaggenau Hausgeräte GmbH Carl-Wery-Straße 34 D-81739 München www.gaggenau.com...