Installation of Jøtul I 80
Mini/ Maxi - Classic,
Harmony and Panorama
Make sure that the fireplace insert is free of damage before
commencing with the installation.

Laying the foundations

If the fireplace is to be built on a wooden floor, there will
usually be neccesary to reinforce the floor to avoid
overloading. The strain on the floor will vary according to
the weight of the masonry surrounding installed.
If a pre-fabricated surrounding is used, most of these will
have a weight which makes laying a foundation
unnecessary. Check with the supplier's catalogues.

Chimney

The connection to the chimney must be done in compliance
with the chimney supplier's assembly instructions.
It is important that the connection is made a little flexible
(i. e: tightening with the aid of a rope seal and furnace
cement) so that cracks do not occur.

The surrounding

Air should be allowed to flow between the insert and the
brickwork. The specified space for air into the base and out
of the top given below and in fig. 2 is the minimum
requirement. This is a safety measure to prevent a build up
of heat in the mantelpiece; and also to ensure sufficient
heat emission into the room.
It is very important that there is an open air supply to the
air intake at the top of the insert.
Ensure that there is a sufficient distance between the
surrounding and the insert´s air vent in order to supply the
insert with a reasonable amount of combustion air.
Jøtul I 80 Mini Classic, Harmony: 350mm
Jøtul I 80 Maxi Classic, Harmony/Panorama: 400 mm
under the ceiling of a flammable material.

Air circulation

Air should be allowed to flow between the insert and the
brickwork. The specified space for air into the base and out
of the top which is given in the text and in fig. 2, is the
minimum requirement. This is a safety measure to prevent
a build up of heat in the surrounding; and also to ensure
sufficient heat emission into the room.
The required air vent sizes for Jøtul I 80 Mini Classic,
Harmony (for air circulation) are:
Base:
Minimum of 350 cm
Top:
Minimum of 600 cm
The required air vent sizes for Jøtul I 80 Maxi Classic,
Harmony/Panorama (for air circulation) are:
Base:
Minimum of 500 cm
Top:
Minimum of 750 cm
The use of a fireplace requires plenty of ventilation to the
room in which the fireplace is situated. If the house is badly
ventilated, the room must be equipped with extra fresh air
circulation, for example by means of a separate channel
under the base of the fireplace. The fresh air channel should
be as straight as possible. It should be possible to close the
channel with a damper in order to keep out cold air when
the fireplace is not being used. A good choice would be
Jøtul's own fresh air damper, catalogue no: 340654. The
channels in the fireplace room must be manufactured in
non-flammable materials. See fig. 2C.

Assembly prior to installation

Attaching the legs (fig. 3) and securing the base heat shield
(fig. 4).
1. Unpack the insert. Take the box out with its contents
and if necessary, the burn plates. Remove both the ash
lip and the bottom frame situated at the rear of the
combustion chamber. Close the door(s).
2. To make the installation easier, remove the entire front
including the doors, air chamber and baffle plate. See
section: Service.
3. Place the wooden pallet and the cardboard packaging
on the floor and lay the fireplace carefully down on its
back.
4. Assemble the 3 legs (A) with the adjustable joints (C)
with the aid of 3 screws and washers, which are in the
plastic bag. Attach the joints to the product with the aid
of 3 countersunk screws (B) M6x25mm and washers.
These are already attached to the base of the fireplace.
Adjust he legs so that the required height is achieved.
5. Assemble the base heat shield (fig. 4 A) under the base
of the fireplace by using 1 nut M6 and washer.
6. Lift the combustion chamber up.
7. NB! The product is heavy. You will need help during
assembly and when the product is being placed into
position.
8. The final adjustments to the legs should only be made
after the insert has had a trial assembly. The bracket
(D) should be placed under the screw heads, both to
protect the surface and to prevent the insert from
slipping out of place. The final adjustment is done with
the aid of M10x45mm screws which are attached to
the joints.
9. Replace the parts you removed in order to make the
handling of the fireplace easier.
10. Place the air distributor (fig. 5) on the base of the
fireplace in such a manner that it covers the holes at
the bottom of the rear burn plate.
ENGLISH
2
free ventilation.
2
free ventilation.
2
free ventilation.
2
free ventilation.
23