Jøtul I 80 Mini Classic Installation And Operating Instructions Manual

Jøtul I 80 Mini Classic Installation And Operating Instructions Manual

Hide thumbs Also See for I 80 Mini Classic:

Advertisement

NO/DK - Monterings- og bruksanvisning
SE
- Monterings- och bruksanvisning
FI
-
Asennusohjeet ja tekniset tiedot
GB
- Installation and Operating Instructions
FR
- Manuel d'installation et d'utilisation
ES
- Instrucciones para instalación
IT
- Manuale di installazione ed uso
DE
- Montage- und Bedienungsanleitung
NL
- Installatie- en montagehandleiding
- Figures/Pictures
Monterings- og bruksanvisningen må oppbevares under hele produktets levetid. These instructions must be
kept for future references. Wir empfehlen Ihnen, die Montage- und Bedienungsanleitung für spätere Zwecke
sorgfältig aufzubewahren. Ce document doit être conservé pendant toute la vie de l'appareil.
Jøtul I 80 Mini/Maxi
Classic, Harmony, Panorama
2
12
21
29
38
47
56
65
74
83

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the I 80 Mini Classic and is the answer not in the manual?

Questions and answers

Summary of Contents for Jøtul I 80 Mini Classic

  • Page 1 Jøtul I 80 Mini/Maxi Classic, Harmony, Panorama NO/DK - Monterings- og bruksanvisning - Monterings- och bruksanvisning Asennusohjeet ja tekniset tiedot - Installation and Operating Instructions - Manuel d’installation et d’utilisation - Instrucciones para instalación - Manuale di installazione ed uso - Montage- und Bedienungsanleitung - Installatie- en montagehandleiding - Figures/Pictures...
  • Page 2: Table Of Contents

    ENGLISH 1.0 Relationship to the Table of contents authorities 1.0 Relationship to the authorities ..... 29 Installation of a fireplace must be according to local codes and 2.0 Technical data ..........29 regulations in each country. 3.0 Safety precautions ........30 All local regulations, including thosethat refer to national and European standards, shall be complied with when installing the product.
  • Page 3: Safety Precautions

    ENGLISH 3.0 Safety precautions 4.0 Installation 3.1 Fire preventive measures 4.1 Floor Any use of the fireplace may represent some danger. Therefore, Foundations respect the following instructions: • Ensure that furniture and other flammable materials do not Ensure that the floor is strong enough for the fireplace. See get too close to the fireplace.
  • Page 4 ENGLISH Be aware of the fact that connections must have a certain For example use: Rock wool 100 mm thick on top of a steel plate min. 0,9 mm. flexibility in order to prevent movement in the installation leading to cracks. N.B.
  • Page 5 ENGLISH Fitting the bottom frame (fig. 5) (Jøtul I 80 Mini/ 4.8 Control of functions (fig. 8) Maxi - Harmony and Panorama) When the product is set up, always check the control functions. These shall move easily and function satisfactorily. 1.
  • Page 6: Use

    ENGLISH 5.0 Use Another important factor for proper fuel consumption is that the logs are the correct size. The size of the logs should be: Kindling: Length: Approx 35-40 cm 5.1 Choice of fuel Diameter: 3-5 cm Amount per fire: 8-10 pieces Always use quality firewood.
  • Page 7: Maintenance

    ENGLISH 6.0 Maintenance • Add the wood and make sure that the air vent is fully open for a few minutes until the wood has caught fire. • Close the air vent once the wood has properly ignited and is burning well. Check that afterburning (secondary 6.1 Cleaning the glass combustion) starts.
  • Page 8: Service

    ENGLISH 7.0 Service 6.6 Exterior maintenance Painted products may change colour after several years usage. Warning! Any unauthorised change to the product is illegal! Only The surface should be cleaned and brushed free of any loose particles before new paint is applied. use original spare parts! Enamelled products must only be cleaned with a clean, dry cloth.
  • Page 9: Problems - Troubleshooting

    ENGLISH 8.0 Reasons for operational 2. Unscrew the screws (A) in the lower front edge of the combustion chamber half way out and pull the washers all the way out towards the screw head. problems - troubleshooting 3. Loosen the screws (B) in the upper front edge of the combustion chamber.
  • Page 10: Optional Equipment

    ENGLISH 9.0 Optional equipment 9.3 Ash compartment cat. no. 340732 (fig. 15) 1. Remove the air distributor (A) and the internal screw in the 9.1 Damper - cat. no. 340955 (fig. 13) middle of the bottom of the combustion chamber so that the fire plate and the cross bar can be removed.
  • Page 12 Fig 3 Fig 2 Fig 4 Fig 6 Fig 5 Fig 9 Fig 7 Fig 8...
  • Page 13 g 10 Fig 11 ig 12 Fig 13 ig 14 Fig 15...
  • Page 16 Jøtul arbeider kontinuerlig for om mulig å forbedre sine produkter, og vi forbeholder oss retten til å endre spesifikasjoner, farger og utstyr uten nærmere kunngjøring. Jøtul bemüht sich ständig um die Verbesserung seiner Produkte, deshalb können Spezifikationen, Farben und Zubehör von den Abbildungen und den Beschreibungen in der Broschüre abweichen. Jøtul pursue a policy of constant product development.

Table of Contents