FITTING UNIT
AIR INLET HOSE
Detail of Hose clip
Plastic tie
Inlet hose
LOCKING
CLAMP
SCREW
CLAMP
AND
INSULATION.
The following
components
can be fitted
by
reaching down the rear of the appliance as it is
positioned against the wail.
1. Connect the flue outlet to the manifold
by
extending the stainless steel sliding tube until it
is fully inserted into the manifold.
I,
/
.
.*
,*
ManiloM
Sliding Tub
Do not extend flue tube
beyond red line.
2. Fit the locking
clamp
over
connection
between sliding tube and manifold. Engage the
hook and rotate it until it snaps against
the
body of the clamp.
flue ou
Sliding
Manifold
P
Lo&g
damp
3. ,Fit the screw clamp between the sliding tube
and the flue elbow.' Secure with the 4 mm screw
supplied.
The flue outlet
is now locked
into
position.
I
I
saew
Locking damp
I
I
Flue Outlet tube
I
I-
I
w
Manifold
4. Slide the insulation
sleeve
up to the flue
manifold, slip the securing clip over the sleeve
as shown.
I
Fit clip
I
A
Ftueelbow '
-2l-