The flue system installation instructions are enclosed with the flue terminal, packaged separately.
This appliance shall be installed in accordance with:
• Manufacturer's Installation Instructions
• Current AS/NZS 5601 AS/NZS 3000
• Local Regulations and Municipal Building Codes including local OH&S requirements
This appliance must be installed, maintained and removed by an Authorised Person.
For continued safety of this appliance it must be installed and maintained in
All Rinnai gas products
are A.G.A. certified.
accordance with the manufacturers instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RHFE-559FDT

  • Page 1 • Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed by an Authorised Person. For continued safety of this appliance it must be installed and maintained in All Rinnai gas products are A.G.A. certified. accordance with the manufacturers instructions.
  • Page 2 Congratulations on the purchase of your Rinnai Energysaver space heater. We trust you will have many years of comfort and enjoyment from your appliance. BEFORE PROCEEDING WITH THE OPERATION OR INSTALLATION OF YOUR NEW HEATER PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF THE REQUIREMENTS, FEATURES AND OPERATION OF YOUR NEW APPLIANCE.
  • Page 3: Table Of Contents

    HUMIDIFIER TRAY ............................13 FAN FILTER(S)............................... 13 CLEANING THE FAN FILTER(S) ........................13 FLUE TERMINAL............................13 SAVE A SERVICE CALL ..........................14 SERVICE ................................ 14 TROUBLE SHOOTING CHECKLIST......................15 ERROR CODES ............................. 15 INSTALLATION MANUAL ........................17 CONTACT INFORMATION .......................28 Rinnai ES_FDT_OIM...
  • Page 4: Before You Start

    Please keep these instructions in a safe place for future reference. FLUE INSTALLATION MANUAL These instructions are to be used in conjunction with the Rinnai “Energysaver Space Heater Co-Axial Flue System Installation Manual” These components Installation Manual” supplied with flue kits ESDFK or ESKIT03.
  • Page 5: Safety

    DO NOT modify this appliance. Modifying from original specifications may create a dangerous situation and will void your warranty. • Only the flue components specified by Rinnai must be used. • Unpack the heater and check for damage. DO NOT INSTALL A DAMAGED HEATER. If the heater is damaged, contact your supplier for advice.
  • Page 6 A dedicated 230V / 240V 50Hz earthed 10 Amp power point must be used with this appliance. DO NOT use power boards or double adaptors to operate this appliance. The appliance MUST NOT BE located below a power point. Rinnai ES_FDT_OIM...
  • Page 7 However if odours persist switch ‘OFF’ the appliance and contact Rinnai. During peak operating periods the filters should be cleaned weekly, however if the “FILTER” warning indicator flashes in the control panel display, turn off the appliance immediately and clean filters before any further use.
  • Page 8: About Your Energy Saver Space Heater

    If a power failure occurs at any time during operation, the appliance will remain OFF once the power is re- instated and the ON/OFF button must be pressed to re-ignite the appliance. Questions? Contact Rinnai using the contact numbers listed on the back cover of this booklet for further advice. Rinnai ES_FDT_OIM...
  • Page 9: Control Panel General Layout

    ABOUT YOUR ENERGY SAVER SPACE HEATER CONTROL PANEL GENERAL LAYOUT RHFE-559FDT RHFE-1005FDT Both Models 'ON' / 'OFF' BUTTON TEMPERATURE DISPLAY Main switch for turning 'ON / OFF'. Shows temperature (Set / Room), or coded error message. SET TEMPERATURE ROOM TEMPERATURE...
  • Page 10: Basic Heater Operation

    15 seconds. After this it will be necessary to press the ‘ON’/’OFF’ button ‘OFF’, then ‘ON’ again. If the appliance fails to ignite after 4 attempts, contact Rinnai as a service call may be required. TO TURN THE UNIT ‘OFF’ Simply press the ‘ON’/’OFF’ button to switch ‘OFF’...
  • Page 11: Economy Mode

    Function Lock is activated, it cannot be turned ‘ON’ again until the Child / Function Lock is deactivated. FAN OPERATION The fan turns ‘ON’ automatically when the heat exchanger warms up and turns “OFF” when it cools down. This helps to prevent cold draughts and maximises efficiency. Rinnai ES_FDT_OIM...
  • Page 12: Additional Heater Operation Information

    The installation also must comply with the instructions CAUTION supplied by Rinnai. This heater must be serviced, installed and removed by an authorised person. No parts or functions should be modified or permanently removed from the heater or its flue.
  • Page 13: Care And Maintenance

    WARNING FLUE TERMINAL Regularly check the outside flue terminal to make sure it is clear from plant growth and from other obstructions. Refer to “SAFETY” on page 7 for additional requirements. IMPORTANT Rinnai ES_FDT_OIM...
  • Page 14: Save A Service Call

    SERVICE Rinnai recommend that this appliance and installation be inspected and serviced every 2 years. If the power supply cord or any other component of the heater are damaged, they must be replaced by Rinnai or a suitably qualified person.
  • Page 15: Trouble Shooting Checklist

    ‘ON’ again. NOTE If the Error Message still remains or returns on the next operation, contact Rinnai or your nearest service agent and arrange for a service call. The Energysaver Range of heaters has the ability to monitor its own operation continuously.
  • Page 16 NOTES Rinnai ES_FDT_OIM...
  • Page 17: Installation Manual

    FLUE TERMINAL LOCATION ........................21 HEATER INSTALLATION .........................22 UNPACKING THE APPLIANCE......................22 CONNECTING THE APPLIANCE TO THE CONSUMER GAS PIPE............. 22 RHFE-559FDT - BACK PANEL INSTALLATION ..................23 RHFE-1005FDT - BACK PANEL INSTALLATION .................. 24 COMMISSIONING ..........................25 INSTALLATION AND COMMISSIONING CHECKLIST ................25 INSTALLATION RECORD ........................
  • Page 18: Installation General

    Ignition Direct continuous spark electronic ignition Electrical 230V / 240V 50Hz earthed 10 Amp, supply lead and 3 pin plug Supply Replace ONLY with Rinnai genuine part Standby Power Consumption <1W Convection Fan Cross Flow Type fan Centrifugal Drum Type fan Temperature Range 16°C to 26°C in 1°C increments...
  • Page 19: Heater Location

    This heater must not be installed where curtains or other combustible materials could come into contact with it. In some cases curtains may need restraining. For all installations, ONLY Rinnai Energysaver Flue components MUST be used. The Rinnai Energysaver MUST NOT be flued into ‘natural draft’ flue system or via a chimney.
  • Page 20: Flue Installation

    FLUE INSTALLATION TYPES OF FLUE INSTALLATIONS Consult the ‘Energysaver Space Heater Co-Axial Flue Systems Installation Manual’ included with the ‘On Wall’ or ‘Direct’ flue kits for detailed flue installation instructions. Use only Rinnai Flue IMPORTANT components with this appliance. The following configurations are currently available. For alternative configurations contact Rinnai.
  • Page 21: Flue Terminal Location

    AS/NZS 5601 was current at the time of printing this Axial Flue System Installation Manual’) manual, but may have been superseded. It is the installers IMPORTANT responsibility to ensure that the current version of this standard is used. Rinnai ES_FDT_OIM...
  • Page 22: Heater Installation

    Refer to the local gas authority for confirmation of gas type if you are in doubt. The heater does not come supplied with flue components. These are purchased separately and ONLY Rinnai Energysaver Co-Axial Flue System Flue components can be used with this NOTE appliance.
  • Page 23: Rhfe-559Fdt - Back Panel Installation

    CAUTION WARNING solution from coming in contact with electrical components. RHFE-559FDT - BACK PANEL INSTALLATION The back panel is NOT an optional component and MUST BE fitted to ensure the correct and safe operation of the appliance while also Left providing concealment and protection of the flue and gas connections.
  • Page 24: Rhfe-1005Fdt - Back Panel Installation

    Rear cover panels MUST BE fitted to ensure correct and safe operation of the appliance. WARNING Failure to fit the rear cover panels will result in iv ii inefficient and dangerous operation of the appliance and void the warranty. Rinnai ES_FDT_OIM...
  • Page 25: Commissioning

    _____________________________________________________________________ Mobile Phone: _____________________________________________________________________ Compliance Details Certificate of Compliance / Certification Number: ______________________________________________ Authorised Persons - Licence Number: _______________________________________________________ Installers Signature: _____________________________________________________________________ Installation Date: _____________________________________________________________________ Appliance Details Model Number: _____________________________________________________________________ Serial Number: _____________________________________________________________________ Installation Address: _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________________________ Rinnai ES_FDT_OIM...
  • Page 26: Final Checklist

    3. The Appliance Test Point (Burner) Pressure is correct for it's particular installation / flue configuration and adjusted if necessary. 4. Have you used only Rinnai Energysaver® flueing components? 5. That the air inlet hose and flue connections are sound? 6.
  • Page 27: Wiring Diagrams

    WIRING DIAGRAMS RHFE-559FDT RHFE-1005FDT Rinnai ES_FDT_OIM...
  • Page 28: Contact Information

    P.O. Box 460 Braeside, Victoria 3195 106316 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance RHF559-1166x01(00) requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced every 2 years.