Flue Sizes; Snow Areas; Standard Installation Of Flue Manifold - Rinnai RHFE-556FTD How To Use Manual

Table of Contents

Advertisement

Do not flue into natural draught flues or fireplaces,
this unit can only be used with one of the six
types of Rinnai flue kits.
Do not flue unit into other rooms.
Flue terminal must be outside.
I
Flue may be positioned
directly
under opening
windows, with a minimum clearance of 150 mm.
FLUE SIZES:
6 Flue lengths are available.
AA flue suits wall
75 -
115 mm
A
flue suits wall 115 - 240 mm
B
flue suits wall 240 - 400 mm
C
flue suits wall 400 - 600 mm
D
flue suits wall 600 - 800 mm
E
flue suits wall 800 - 1000 mm
Co-ax flue also available.
SNOW AREAS
4
.d
,
,I
In areas subject to heavy snowfall,
keep snow
clear of flue terminal at all times.
STANDARD INSTALLATION
OF FLUE MANIFOLD.
Diagram below shows minimum clearances
and
distances
from obstructions.
Also check local
regulations.
Flammable
m
I
130Omm
Side Clearances
500 mm
I
I -l
FIT BACK COVERS (SIDES ONLY)
Fit back covers (sides only) as shown below.
GAS CONNECTI
with
Fit suitable copper flare elbow to appliance inlet.
-17
-