General rules

Inspections
The machine must be inspected according to the "Guidelines for Liquid Spray
Devices" at least once every 12 months by a qualified person, to ensure that
continued safe operation is guarateed.
The results of the inspection are to be recorded in writing.
This may be done in any form.
Accident prevention
The machine is designed for accidents to be impossible if used correctly.
The operator is to be notified of the risk of injury from hot machine parts and the
high pressure water jet. The "Guidelines for Liquid Spray Devices" must be
complied with. (see pages 16 and 17)
Check the oil level at the oil dip stick prior to each use (see also page 11).
(Ensure horizontal position!)
Oil change:
The first oil change should be carried out
after approximately 50 operating hours,
then every year or after 1000 operating
hours. If the oil turns grey or white, you
must certainly change the oil of your high
pressure pump.
Open the oil discharge screw at the
bottom of the device over a collection
resevoir.
Put the machine into a horizontal position
to drain the oil. The oil is to be caught in
the reservoir and disposed of in an
approved manner.
New Oil: 1,0 l -
Motor oil: 10/W60 SAE halfsynthetic oil
Guarantee
The guarantee is 12 months according to VDMA for manufacturing errors
The guarantee is void if changes are made to the safety devices or if the machine is
used at excess temperatures or speeds. The guarantee is also void if the machine
is used with a voltage below the required rating, with less than the required amount
of water or with dirty water. Manometer, nozzle, valves, sleeves, high pressure hose
and spray equipment are wear parts and are not covered by the warranty.
Our operating instructions must be complied with.