Filling the cooling system.
- Connect the hoses.
- Fill the circuit with 1.4 L of coolant.
- Loosen the bleeder screw (2) to remove air
contained in the engine.
- Close the bleeder screw.
Tightening torque: 0.3 m.daN.
- Start the engine and accelerate in order to
warm it up.
- Stop the engine once it reaches its operating
temperature. Approximately 90°C
- Check the coolant level in the header tank.
- If necessary add coolant in the header tank
A. Maximum level.
B. Minimum level.
Note: Check the level with the machine par-
ked on its centre stand, on level
ground.