Installer Function Keys

To access the Installer Function keys, press:
[
]+[
] + [
ENTER
INSTALLER CODE
monitoring station.
[
]+[
] + [
ENTER
INSTALLER CODE
monitoring station until the next reportable event.
[
]+[
] + [
ENTER
INSTALLER CODE
station that is using the WinLoad software.
[
]+[
] + [
ENTER
INSTALLER CODE
in order to initiate communication with a computer using the WinLoad software.
[
]+[
] + [
ENTER
INSTALLER CODE
squawk to indicate opened zones. Press the [

Trouble Display

- Press the [
] key to view the Trouble Display. Please note that the keypad can be programmed to emit a beep every 5 seconds
TBL
whenever a new trouble condition has occurred. Press the [
- To view the sub-menu, press the corresponding key in the main menu.
Main Menu Trouble
[2] Power trouble
[3] Bell trouble
[4] Communication trouble
[5] Tamper and zone wiring failure
[6] Module tamper trouble
[7] Fire loop trouble
[8] Timer loss
[0 (10)] or [10] Module supervision loss
[16] Keypad fault (K32 only)
[
] Keypad fault (K636 / K10V/H only)
SLEEP
30
] = Test Report: Send the "Test Report" report code programmed in section [875] (page 25) to the
MEM
] = Cancel Communication: Cancels all communication with the WinLoad software or with the
STAY
] = Answer WinLoad Software: Will force the console to answer an incoming call from the monitoring
SLEEP
] = Call WinLoad Software: Will dial the PC telephone number programmed in section [915] (page 15)
BYP
] = Installer Test Mode: The installer test mode will allow you to perform walk tests where the siren will
TBL
] key again to exit.
TBL
] key to stop the beeping.
TBL
Sub-Menu Trouble Menu
[1] Low/No battery on the control panel
[2] AC failure on control panel
[3] Auxiliary overload on control panel
[8] Low power on GSM communication module
[1] Bell disconnect on control panel
[2] Bell overload on control panel
[1] Telephone Line Monitoring on control panel
[2] Fail to communicate on Monitoring Telephone 1 on control panel
[3] Fail to communicate on Monitoring Telephone 2 on control panel
[4] Fail to communicate on pager telephone on control panel
[5] Fail to communicate on voice telephone on control panel
[6] Fail to communicate with PC on control panel
[7] Fail to communicate with IP receiver 1 or 2 (GPRS) (E65 panels only)
[8] Fail to communicate with IP receiver 1 or 2 (IP) (E65 panels only)
[9] GSM no service (GSM network failure)
[10] IP Module No Service (network failure) (E65 panels only)
[STAY] GSM RF jamming
[OFF] IP Receiver Unregistered (IP/GPRS) (E65 panels only)
[1] to [32] Zones in tamper and zone wiring failure
[2] Keypad bus
[3] ZX8 bus module
[6] GSM bus module
[1] to [32] Zones in fire loop trouble
[2] Keypad bus (Panel reset will not clear this trouble, clear it in
section [955] on page 2.)
[3] ZX8 bus module
[7] PGM4 bus module
[8] VDMP3
[9] PCS100
[10] IP100 (E65 panels only)