Entering Programming Mode; Data Entry & Display - Paradox Esprit 728ULT Programming Manual

4 to 32 zone security systems
Hide thumbs Also See for Esprit 728ULT:
Table of Contents

Advertisement

Entering Programming Mode

1.
Press [
].
ENTER
2.
Enter your [
INSTALLER CODE
To modify codes, see System Codes on page 31.
3.
Enter 3-digit [
] you wish to program. [
SECTION
4.
Enter required [
].
DATA
WARNING: StayD Mode must be deactivated in order to enter programming mode. To deactivate StayD, press [
[
].
OFF
Data Entry & Display
To access the Data Display Mode, press the [
The three keys / four LEDs as indicated below will begin to flash indicating that you are in the Data Display Mode.
K636
Each time the [
] key is pressed, the keypad will display the next digit in the current section and will continue through all the
ENTER
following sections one digit at a time without changing the programmed values. Not available for sections using the Multiple Feature
Select Method. Press the [
CLEAR
There are two methods that can be used to enter data when in programming mode: Single Digit Data Entry and Feature Select
Programming methods:
Single Digit Data Entry Method
After entering programming mode, some sections will require that you enter decimal values from 000 to 255. Other sections will require
that you enter hexadecimal values from 0 to F. The required data will be clearly indicated in this manual. When entering the final digit in a
section, the panel will automatically save and advance to the next section.
Feature Select Programming Method
After entering certain sections, eight options will be displayed where each option from [1] to [8] represents a specific feature. Press the
key corresponding to the desired option. This means the option is ON. Press the key again to remove the digit, thereby, turning OFF the
option. Press the [
] key to set all eight options to OFF. When the options are set, press the [
CLEAR
next section.
Important Settings and Modes
Section
Description
[950]
Reset all programmable sections to factory default values
[955]
Clear bus module trouble (remove disconnected module from the bus)
[970]
Download memory key into panel (see the Reference & Installation Manual)
[975]
Upload panel into the memory key (see the Reference & Installation Manual)
[980]
Display version number of the panel (see Viewing Version Numbers on page 3)
2
] (default: 000000) or [
MAINTENANCE CODE
] and [
ARM
] key after entering a section and before entering any data.
ENTER
K10V/H
] key at any time to exit the Data Display Mode.
] (no default). [
] lights are ON.
STAY
K32I
] and [
] lights flash.
ARM
STAY
] key to save and advance to the
ENTER
Programming Guide
] + [
] +
OFF
CODE
K32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Esprit e65Esprit e55

Table of Contents