Solution System; Maintenance; Flow Control Valve Replacement - Ba 700 / 28Lx / 280Hd - Nilfisk-Advance BA 1000 Service Manual

Table of Contents

Advertisement

_________________________________________________________________________________________________________________

MAINTENANCE

The solution system should be flushed every day to prevent a build-up of soap residue in the solution valve. To flush the
system...
1
Park the machine near a designated "DISPOSAL SITE" and drain the solution tank.
2
Put clean, warm water into the solution tank and let it drain through the drain hose.
3
When the tank is empty, re-cap the drain hose and put about 2 inches (5 cm) of clean, warm water in the tank.
4
Put the machine controls in the following positions:
Key Switch (11) - ON
Solution Switch (20) - ON
Brush Drive (18) - Lowered
Twist Grips (2) - Forward slightly
Solution Flow Control Lever (1) - Pulled Back
5
Let all of the clean water flow from the tank. This will flush dirt and soap residue from the electric solenoid valve and
the flow control valve.
______________________________________________________________________________________________

FLOW CONTROL VALVE REPLACEMENT - BA 700 / 28LX / 280HD

1
Drain the solution tank at a designated
"DISPOSAL SITE".
2
See Figure 1. Remove the (A), (B), and (C)
Hoses from the solution valve fittings and
mark them to ensure proper reassembly.
3
Remove Ball Joint (D) from the valve arm.
Be careful not to lose the bushings.
4
Remove the valve mounting bolts and re-
move the valve from the machine.
5
Remove the fittings from the old valve and
remove the valve from the mount, (note the
positioning of the fittings for reassembly).
6
Install the new valve on the mount and
install the fittings.
FORM NO. 56043025 / BA 700, 800, 1000 / 28LX, 32LX, 38LX / 280HD, 320HD, 380HD - 11

SOLUTION SYSTEM

FIGURE 1