Code Faults
L30
DEF.FLUE GAS
PRESSURE
L31
DEF.SMOKE.TEMP
L32
DEF.OUTLET S.
L33
DEF.OUTLET S.
L34
BACK S.FAILURE
L35
BACK S.FAILURE
L36
DEF.FLAME LOS
L37
SU COM.FAIL
L38
PCU COM.FAIL
L39
BL OPEN FAIL
L250 DEF.WATER MIS.
L251 MANOMETRE FAIL
D03
OUTL S.B FAIL.
D04
OUTL S.C FAIL.
15/07/2015 - 300026440-05
Cause
Description
of the
fault
PCU
The flue gas pressure switch
opened 5 times in 24 hours.
PCU
The maximal smoked temperature
is exceeded of 5 times in 24 hours.
PCU
The boiler flow sensor has short-
circuited
PCU
The boiler flow sensor is on an open
circuit
PCU
The return temperature sensor has
short-circuited
PCU
The return temperature sensor is
on an open circuit
PCU
3 flame losses during a heating
demand
PCU
Communication breakdown with
the safety box
PCU
Communication failure between the
PCU and SCU PCBs
PCU
The BL inlet opened for a short time Bad connection
PCU
The water pressure is too low
PCU
Fault on the water pressure sensor Wiring problem
SCU
Circuit B flow sensor fault
Circuit C flow sensor fault
Remarks:
The circuit pump is running.
The 3-way valve motor on the
circuit is no longer powered and can
be adjusted manually.
Checking / solution
Contact the professional who takes care of
4
maintenance of the appliance
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
SCU PCB not connected or faulty
Contact the professional who takes care of
4
maintenance of the appliance
External cause
Parameter incorrectly set
Contact the professional who takes care of
4
maintenance of the appliance
Hydraulic circuit incorrectly vented
Water leak
Measurement error
Top up with more water if necessary
4
Reset the boiler
4
Failure water pressure switch
Sensor pcb defect
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
7. Troubleshooting