DeDietrich AFC 30 User Manual page 38

Oil-fired condensing boilers
Hide thumbs Also See for AFC 30:
Table of Contents

Advertisement

7. Troubleshooting
Code Faults
L00
PSU FAIL
L01
PSU PARAM FAIL
L02
STB OUTLET
L03
DEF.OIL.SENSOR
L04
BURNER FAILURE
L05
DEF.INTERNAL
L06
DEF.SPEED.MOT
L07
DEF.T.WARM UP
L08
PARASIT FLAME
L09
OIL.PRES FAIL.
37
Cause
Description
of the
fault
PCU
The PSU integrated in the SU is
defective
PCU
The safety parameters are incorrect Parameters faulty
SU
Boiler temperature too high
SU
The oil pressure measurement
sensor is faulty
SU
Burner start-up failure
SU
Internal SU fault
SU
Fault on the burner motor
SU
Preheating period exceeded
SU
Detection of a parasite flame
SU
Oil pressure over limit
AFC 18 - AFC 24 - AFC 30
Checking / solution
Parameters faulty
Contact the professional who takes care of
4
maintenance of the appliance
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
No water circulation
Vent the air in the heating system
4
Check the circulation (direction, pump,
4
valves)
Check the water pressure
4
Bad connection
The oil pressure measurement sensor is faulty
Contact the professional who takes care of
4
maintenance of the appliance
No ignition
Contact the professional who takes care of
4
maintenance of the appliance
No flame signal.
Air present in the oil circuit.
Check that the oil valve is actually open
4
Contact the professional who takes care of
4
maintenance of the appliance
Presence of the flame but insufficient ionization
(<3 µA)
Check that the oil valve is actually open
4
Contact the professional who takes care of
4
maintenance of the appliance
The safety control box on the burner is defective
Contact the professional who takes care of
4
maintenance of the appliance
The safety control box on the burner is defective
Contact the professional who takes care of
4
maintenance of the appliance
The burner motor is defective
Contact the professional who takes care of
4
maintenance of the appliance
The reheat fuel oil is defective
Contact the professional who takes care of
4
maintenance of the appliance
The safety control box on the burner is defective
Contact the professional who takes care of
4
maintenance of the appliance
Signal present whilst there is no flame
Contact the professional who takes care of
4
maintenance of the appliance
Contact the professional who takes care of
4
maintenance of the appliance
15/07/2015 - 300026440-05

Advertisement

Table of Contents
loading

This manual is also suitable for:

Afc 18Afc 24

Table of Contents