Introduction
Your Baxi Bermuda SL3 is a central
heating boiler combined with a gas
fire. Normally the fire will heat the
room in which it is situated and the
boiler will provide heating for the rest
of the house and also domestic hot
water if required. The boiler and fire
are independently controlled.
The boiler may be controlled by an
external programmer or clock control
(see separate instructions with the
clock controller used). The fire is
controlled by the knob which is
located on the right hand side of the
outer case.
Important Notice
The
Bermuda
SL3
appliances are for use on PROPANE
GAS ONLY and cannot be used on
any other gas. Propane appliances
can be converted to operate on
Natural Gas if required at a later date.
Consult your Installer.
WARNING
Bermuda SL3 Renewal Firefronts
MUST
NEVER
be
independent gas fires without the
boiler.
Important Information
This product uses a fuel effect coal bed
containing Refractory Ceramic Fibres
(R.C.F.) which are man-made vitreous
silicate fibres. Excessive exposure to
these materials may cause temporary
irritation to eyes, skin and respiratory
tract. Care must be taken when handling
these articles to ensure the release of
dust or fibres is kept to a minimum. Refer
to the section Cleaning the Fire.
NOTE: When your Bermuda is first used it is
possible that certain smells may be emitted.
These smells will quickly clear with use. As the
fire is used more and more, the bright finished
metal around the coal bed will begin to darken.
This is perfectly normal and will enhance the
realism of the coal and flame effect.
Most heating appliances generate warm air
convection currents and transfer heat to any
wall surface against which they are situated.
Some soft wall furnishings (such as blown
vinyl wallpapers) may not be suitable for use
where they are subjected to temperatures
above normal room levels. The manufacturers
advice should be sought before using this type
of wall covering adjacent to any heating
appliance. The likelihood of wall staining from
convected air currents will be increased in
environments where high levels of tobacco
smoke or other contaminants exist.
Pilot Viewing Window
Indicator Light
Electronic Controls Boiler
(51/5)
Controls Cover
Panel
Bermuda SL3
Propane
fitted
as
Bermuda SL3 shown with
Controls Cover Panel removed
Pilot Viewing Window
(401 Boiler)
Plug &
Socket
Igniter Button
Manual Controls Boiler
(401, 552 & 553 Propane)
Pilot Viewing Window (Series 4)
Igniter
Button
Thermostat Knob
Manual Controls Boiler
(45/3M, 57/3M, 45/4M & 57/4M)
Pilot Viewing Window (Series 4)
Boiler Lockout Light
Pilot Indicator Light
Thermostat
Electronic Controls Boiler
Knob
(45/3E, 57/3E, 45/4E & 57/4E)

OPERATING THE UNIT

Position
Indicator
Button
Fire Control Knob
Boiler Controls
Pilot Viewing Window
(552Boiler & 553
Propane)
Service
Tap
Grey Push
Thermostat
Button
Knob
Service Tap
Pilot Viewing
Grey Push
Mirror (Series 3)
Button
Service
Thermostat
Knob
Tap
page 4
1
Push in and turn the fire control
knob to the OFF position ( ).
2
Remove the controls cover panel
at the bottom of the fire below the
coal bed by grasping it firmly by its
side edges and pulling forwards.
3
Turn the boiler thermostat knob
to the OFF position ( ).
Manual
Electronic
Controls
Controls
Boiler
Boiler
4
Ensure the main gas and
electricity supplies are turned on.
5
TO LIGHT THE BOILER PILOT:
(Manual Controls Boiler) Hold in
the grey push button on the gas
control valve. Looking through the
pilot viewing window or mirror: Press
the igniter button and release. Repeat
until the pilot lights.Continue to hold in
the grey push button for a further 15
seconds. The pilot should stay alight.
NOTE:
If the pilot fails to remain alight or
is extinguished at any time, wait at least 3
minutes then repeat step 5. Once the pilot
is alight it may be left on permanently.
Igniter Button
6
TO
LIGHT
THE
(Manual
Controls
Ensure that all external controls, e.g.
room thermostat, timer etc., are
calling for heat. Turn the boiler
thermostat knob to the desired
position.
7
TO
LIGHT
THE
(Electronic Controls Boiler)
Ensure that all external controls, e.g.
room thermostat, timer etc., are
calling for heat. To operate the pilot
turn the thermostat knob to the
desired position. The indicator light
on the control box will illuminate once
the pilot is lit. The burner will also
light shortly after the pilot has been
established.
To adjust the boiler temperature:
Turn the boiler thermostat knob
clockwise to the required setting. The
optimum boiler thermostat setting
depends upon type of system,
external
controls
requirements. Your Installer will be
able to advise you on this matter.
If the boiler cannot be lit by the
above method consult your
Service Engineer.