Operating The Unit - Baxi Bermuda RG3 Renewal User's Operating

Fireside gas central heating unit natural gas & renewal
Table of Contents

Advertisement

Introduction
Your Baxi Bermuda RG3 is a
central heating boiler combined
with a gas fire. Normally the fire
will heat the room in which it is
situated and the boiler will provide
heating for the rest of the house
and also domestic hot water if
required. The boiler and fire are
independently controlled.
The boiler may be controlled by an
external programmer or clock
control (see separate instructions
with the clock controller used). The
fire is controlled by the knob which
is located on the right hand side of
the outer case.
Important Notice
The Bermuda RG3 is for use on
NATURAL GAS ONLY.
WARNING
The Bermuda RG3 Renewal
Firefront MUST NEVER be fitted
as an independent gas fire
without the boiler.
Pilot Viewing Window
(552 Boiler)
Pilot Viewing
Window (401 Boiler)
Plug &
Socket
Thermostat
Igniter Button
Knob
Manual Controls Boiler
(401, 552 & 553 Propane)
Pilot Viewing Window (Series 4)
Igniter
Pilot Viewing
Button
Mirror (Series 3) Grey Push
Thermostat Knob
Manual Controls Boiler
(45/3M, 57/3M, 45/4M & 57/4M)
Pilot Indicator Light
Boiler Lockout
Pilot Viewing Window
Light (Series 4)
(Series 3)
Electronic Controls Boiler
(45/3E, 57/3E, 45/4E & 57/4E)
Hearth
Handle
Service
Tap
Important Information
Grey Push
Button
This product uses a fuel effect
coalbed
Ceramic Fibres (R.C.F.) which are
man-made vitreous silicate fibres.
Excessive
materials may cause temporary
irritation to eyes, skin and respiratory
tract. Care must be taken when
handling these articles to ensure the
release of dust or fibres is kept to a
Service Tap
minimum. Refer to the section
"Cleaning the Fire".
Button
Pilot Viewing
Pilot Viewing Window
Window (Series 4)
Service
Tap
Thermostat
Knob
Electronic Controls Boiler
(51/5)

OPERATING THE UNIT

Lamp Box
Rotate Lamp Box
Handle
Forward Using The
Handles Provided
containing
Refractory
exposure
to
Indicator Light
Thermostat
Knob
page 4
1
Turn the fire control knob to the
OFF position
off and allow the fire to cool.
2
Remove the fire hearth by
grasping it on either side at the
bottom, and pulling towards you. This
will release the clips and allow the
hearth to be lifted away by drawing it
forward.
3
The lamp box, which is clipped at
the top and hinged at the bottom,
can now be rotated forward to expose
the boiler controls. Use the handles
provided.
4
Turn the boiler thermostat control
knob to the off position (
Manual
Controls
Boiler
5
Turn on the main gas & electricity
supplies to the appliance.
6
TO LIGHT THE BOILER PILOT:
(Manual Controls Boiler) Hold in
the grey push button on the gas
control valve. Looking through the
pilot viewing window or mirror: Press
the igniter button and release. Repeat
until the pilot lights.Continue to hold in
the grey push button for a further 15
seconds. The pilot should stay alight.
NOTE:
If the pilot fails to remain alight or
is extinguished at any time, wait at least 3
minutes then repeat step 6. Once the pilot
is alight it may be left on permanently.
Igniter Button
these
7
TO
LIGHT
(Manual
Ensure that all external controls, e.g.
room thermostat, timer etc., are
calling for heat. Turn the boiler
thermostat knob to the desired
position.
8
TO
LIGHT
(Electronic Controls Boiler)
Ensure that all external controls, e.g.
room thermostat, timer etc., are
calling for heat. To operate the pilot
turn the thermostat knob to the
desired position. The indicator light
on the control box will illuminate once
the pilot is lit. The burner will also
light shortly after the pilot has been
established.
If the boiler cannot be lit by the
above method consult your
Service Engineer.
, switch the bulbs
).
Electronic
Controls
Boiler
Grey Push Button
THE
BOILER:
Controls
Boiler)
THE
BOILER: