Download Print this page

Maintenance - Valor 4191 Owner's Manual

Inset live fuel effect gas fires with ultimate fireslide or fusion front
Hide thumbs Also See for 4191:

Advertisement

Fig. 11. Battery fitting
8

MAINTENANCE

Battery replacement
This appliance requires 9V PP3 Ever Ready Silver Seal (or equivalent)
battery.
To replace the battery remove the bottom front cover casting.
Fit the new battery firmly to the connections on the generator, the
positive battery terminal (+) being to the right as you insert. The guide
plate will help to locate the battery.
Regular maintenance
In order to achieve and maintain high levels of personal safety and performance
efficiency, it is essential that the opening at the back of the fire and the flue are kept clear
of any form of obstruction. It is possible that deposits of mortar or soot could fall and
accumulate causing the flue to be blocked or restricted and so preventing proper
clearance of dangerous exhaust fumes.
In the United Kingdom it is the law that a landlord must have any gas appliance, flue
and pipework which is situated in a tenant's premises checked for safety at least every
twelve months by a competent person (In the U.K, a CORGI registered installer).
We recommend that all gas appliances and their flues, wherever situated, are checked
annually.
Servicing
• In the United Kingdom servicing can be carried out either by a Valor Service
engineer or a CORGI registered installer.
• If you require your fire to be serviced, please contact Valor Service on 0121 386
6203 and quote the following details;
a) - model name and number.
b) - appliance serial no. (To be found on a chained plate below the burner and behind
the bottom front cover)
• If you wish to replace any of the owner replaceable parts listed below, please contact
Valor Sales on 0121 386 6260 for your nearest stockist of these parts. When ordering
please quote the part number shown below.
• From the Republic of Ireland call 0044 121 373 8111 for all enquiries.
Description
Rear wall
Front base coal halves
Rear base coal
Pack of 7 top coals
Right side wall
Left side wall
When fitting replacement parts, follow the instructions contained in this guide. It is
important that only Valor approved parts are used for maximum safety.
(See fig 11).
Part No
545999
546009
563359
563369
546039
546049