CARE AND MAINTENANCE
Plasma
(optional)
Open the panel and take down the
Plasma filter by holding the upper of
the Plasma and lifting it upwards
according to the arrows.
Air filter(optional)
Releasing the buckles as indicated with
arrows and open the cover of the
Plasma, clean or replace the filter.
? For the models with plasma, do not touch the plasma
within 10 minutes after you open the panel.
5. Install the air freshening filter back into position.
6. Insert the upper portion of air filter back into the
unit, taking care that the left and right edges line up
correctly and place filter into position.
Replacement of air filter and air freshening filter
1. Remove the air filter.
2. Remove the air freshening filter.
3. Install a new air freshening filter.
4. Reinstall the air filter and securely close the front
panel.

Preparation for extended non-operation

If you plan to idle the unit for a long time, perform
the following:
(1) Clean the indoor unit and filters.
(2) Operate the fan for about half a day to dry the
inside of the unit.
(3) Stop the air conditioner and disconnect power.
(4) Remove the batteries from the remote controller.
The outdoor unit requires periodic maintenance
and cleaning. Do not attempt to do this yourself.
Contact your dealer or service provider.
2

Pre-season inspection

Check that the wiring is not broken off or
disconnected. Clean the indoor unit and filters.
Check that the air filter is installed.
Check if the air outlet or inlet is blocked after
the air conditioner has not been used for a
long time.
Caution
Do not touch the metal parts of the unit
when removing the filter. Injuries can occur
when handling sharp metal edges.
Do not use water to clean inside the air
conditioner. Exposure to water can destroy the
insulation, leading to possible electric shock.
When cleaning the unit, first make sure that
the power and circuit breaker are turned off.
Do not wash air filter with hot water at more than
O
O
40
C/104
F. Shake off moisture completely and
dry it in the shade. Do not expose it directly to
the sun, it may shrink.