Replacing The Starter Rope And Rewind Spring - Stihl MS 192 T Instruction Manual

Hide thumbs Also See for MS 192 T:
Table of Contents

Advertisement

Available languages

Available languages

Rectify problems which have caused
fouling of spark plug:
Too much oil in fuel mix.
N
Dirty air filter.
N
Unfavorable running conditions,
N
e.g. operating at part load.
Fit a new spark plug after approx. 100
operating hours or earlier if the
electrodes are badly eroded.
WARNING
To reduce the risk of fire and burn injury,
use only spark plugs authorized by
STIHL. Always press spark plug boot (2)
snugly onto spark plug terminal (1) of the
proper size. (Note: If terminal has
detachable SAE adapter nut, it must be
attached.) A loose connection between
spark plug boot and ignition wire
connector in the boot may create arcing
that could ignite combustible fumes and
cause a fire.
MS 192 T, MS 192 TC
Replacing the Starter Rope
and Rewind Spring
Replacing a broken starter rope
Take out the screws (1).
N
Remove the fan housing from the
N
crankcase.
1
Models with stardard starter
2
3
4
Models with ErgoStart
4
4
Use a screwdriver or suitable pliers
N
to remove the spring clip (2) from
the starter post.
Carefully remove the rope rotor with
N
washer (3) and pawl (4).
WARNING
The rewind spring may pop out and
uncoil during this operation – take care
to avoid risk of injury.