Using an EXtra Device Port
Connecting to a Slave DPT
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Back View of DPTs
TO DIGITAL
TO MAIN UNIT
/ PABX
Master DPT
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Master DPT
Cable
Maximum Distance
ø 0.4 mm:
30 m
ø 0.5 mm:
50 m
ø 0.6 mm:
60 m
CAT 5:
50 m
To DLC8/DLC16 card
To DHLC8 card
(for connection of SLT)
3.8.3 Digital EXtra Device Port (Digital XDP) Connection
2-conductor wiring cord
Connect pins "T" and "R".
Slave DPT
Slave DPT
To SLT
SLT
TO MAIN UNIT
/ PABX