Download Print this page

Technical Specifications - HP ProLiant MicroServer Generation 8 Quickspecs

Hide thumbs Also See for ProLiant MicroServer Generation 8:

Advertisement

QuickSpecs

Technical Specifications

System Unit
Dimensions (H x W x
D) (with feet)
Weight (approximate) Maximum
Input Requirements
(per power supply)
BTU Rating
Power Specifications
Power Supply Output
(per power supply)
System Inlet
Temperature
DA - 14565 Worldwide QuickSpecs — Version 24 — 12.17.2015
HPE ProLiant MicroServer Generation 8 (Gen8)
9.15 x 9.06 x 9.65 in (23.24x 23 x 24.5 cm)
(all hard drives, power
supply and processor
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Advisor
which is available via the online tool located at URL:
http://www.hp.com/go/hppoweradvisor
Rated Steady-State
Power
Maximum Peak Power
Operating
21.60 lb (9.8 kg)
15.13 lb (6.8 kg)
100 -- 127 VAC,
200 - 240 VAC
3.5 A (at 110 VAC),
2 A (at 200 VAC)
50 to 60 Hz
For 150W Power Supply
192 W (at 100 VAC),
185 W (at 200 VAC)
For 200W Power Supply
243 W (at 100 VAC),
237 W (at 200 VAC)
For 150 W Power Supply
682 BTU/hr (at 100 VAC),
665 BTU/hr (at 200 VAC)
For 200 W Power Supply
838.86 BTU/hr (at 100 VAC),
825.22 BTU/hr (at 200 VAC)
For 150 W Power Supply
150 W (at 100 VAC),
150 W (at 200 VAC)
For 200 W Power Supply
200 W (at 100 VAC),
200 W (at 200 VAC)
For 150 W Power Supply
150 W (at 100 VAC),
150 W (at 200 VAC)
For 200 W Power Supply
200 W (at 100 VAC),
200 W (at 200 VAC)
10° to 35°C (50° to 95°F) at sea
level with an altitude derating of
1.0°C per every 305 m (1.8°F per
every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no
direct sustained sunlight. Maximum
rate of change is 10°C/hr (18°F/hr).
The upper limit may be limited by the
type and number of options installed.
System performance may be
Page 30

Advertisement