[11] USER PROGRAM
The conditions of factory setting can be changed according to the use conditions.
1. Functions that can be set with user programs
Function
Auto clear
• When a certain time is passed after completion of copying, this function returns to the initial state
automatically. The time to reach the initial state can be set in the range of 30 sec to 120 sec by the unit
of 30 sec. This function can be disabled.
Pre-heat
• When the copier is left unused with the power ON, the power consumption is automatically reduced to
about 40Wh/H (* Note).The time to start this function can be set in the range of 30 sec to 90 sec by the
unit of 30 sec. This function cannot be disabled.
• When this function is operated, the pre-heat lamp on the operation panel lights up. To return to the
initial state, press any key on the operation panel. (When the COPY button is pressed, a copy is made
after returning to the initial state.)
Auto shut off passing
• When the copier is left unused with the power ON, the power consumption is automatically reduced to
time
about 18Wh/H (* Note). The time to start this function can be set in the range of 2 min to 120 min.
• When this function is operated, all the lamps except for the pre-heat lamp on the operation panel turn
off. To return to the initial state, press the COPY button.
Stream feeding
Only models with SPF
Auto shut off setting
• Used to set or cancel this function.
Auto/Manual mode
• Used to set the resolution in the auto/manual mode. The speed priority (300dpi) and the resolution
resolution setup
priority (600dpi) are effective for fine text and ultra fine text.
* Note: The power consumption values in pre-heat and auto shut off may be varied depending on the use conditions.
2. Change the setting
Example: Changing the time to operate the auto clear function
(Change from 60 sec to 90 sec)
1) Press the right and the left exposure adjustment keys simulta-
neously to start setting.
• Keep pressing the keys for 5 sec.
• Display lamps (
,
,
played on the copy quantity display.
2) Select the function code with the 10-digit key (copy quantity set
key).
• The number of the selected function blinks on the digit of 10 on the
copy quantity display.
• For auto clear, select " 1. "
• For setting, refer to the following function codes.
Function name
Auto clear
Pre-heat
Auto shut off passing time
Stream feeding
Auto shut off setting
Auto/Manual mode resolution setup
[Cancel]
If a wrong code is entered, press the clear key and enter the
correct function code.
* SPF only
3) Press the COPY button.
• The number blinking on the digit of 10 of the copy quantity display is
lighted.
• The number of the current set code blinks on the digit of 1.
4) Select the setting code with 1-digit key (copy quantity set key).
• To set to 90 sec, select " 3. "
• For setting, refer to the following set codes.
) blink simultaneously and " -- " is dis-
Function code
1
2
3
4*
5
6
AL-1551CS USER PROGRAM 11 - 1
Contents
Function name
Auto clear
Pre-heat
Auto shut off
Stream feeding
Auto shut off setting
Auto/Manual mode resolution setup
* Factory setting
• The number blinking on the digit of 1 of the copy quantity display is lit
up. This means the setting is completed.
[Cancel]
When a wrong number of the function code is set, press the
clear key and perform the procedure again from step 2.
5) Press the COPY button.
• The number blinking on the digit of 1 of the copy quantity display is lit
up. This means the setting is completed.
Note: To set another function, press the clear key after completion of
this operation and perform the procedure from step 2.
6) Press either one of the exposure adjustment keys (
complete the setting.
• Display lamps (
,
returns to the normal state.
Factory setting
60 sec
30 sec
5 min
300 dpi
Set code
0 (OFF)
1 (10 sec)
2 (30 sec)
*3 (60 sec)
4 (90 sec)
5 (120 sec)
*0 (30 sec)
1 (60 sec)
2 (90 sec)
0 (2 min)
*1 (5 min)
2 (15 min)
3 (30 min)
4 (60 min)
5 (120 min)
0 (Cancel)
*1 (Setting)
0 (Cancel)
*1 (Setting)
*0 (300 dpi)
1 (600 dpi)
,
) go off and the copy quantity display
Set
Set
or
) to